Printing, Printer output – DeFelsko PosiTector 6000 v.4.0 User Manual
Page 20
![background image](/manuals/366627/20/background.png)
20
average, standard deviation, number of
readings, minimum thickness reading and
maximum thickness reading are
simultaneously displayed and stored in
memory. Again, statistical summaries are
calculated for each batch during printing.
This delivers the average of a set of
average readings as required by SSPC
PA-2 guidelines.
NOTE:
SSPC is a U.S.-based Society
for Protective Coatings. PA-2 is a Paint
Application specification.
Printing
Memory(3) models only
Data can be sent from the 6000 to a serial
printer, data collector or computer using
the supplied RS232 serial cable -- or
directly to the optional wireless HP IR
printer using the Gage’s built-in IR port.
Printer Output
Select
PRINT?
PRINT?
Choose an output option:
ALL
ALL: individual readings + Statistical
Summary
HISTO
HISTO: Statistical Summary + Histogram
Select
IR PRT
IR PRT for the HP IR Printer --
or –
Select a
TYPE
TYPE as below if printing to a
serial printer or computer. If uncertain
which
TYPE
TYPE to use, try each one, one at
a time.
TYPE
BAUD
Handshake
TYPE 1
9600
Xon/Xoff
TYPE 2
9600
DTR
TYPE 3
1200
Xon/Xoff
TYPE 4
1200
DTR
Each batch (group of measurements) is
printed separately. The mean, max/min