Dquick trouble-shooting checklist – Star Water Systems EL10S User Manual
Page 20
20
CARE AND MAINTENANCE
Winterizing
CAUTION: Drain the entire system if
there is danger of freezing. A drain plug is
provided at the bottom of the pump case for
this purpose. (
Fig 1).
IL1111
PREVENT
PUMP
DAMAGE!
Remove plug
in freezing
weather
1
Please review the following troubleshooting questions before returning a pump as defective.
If you have any questions, please call Customer Service at (800) 742-5044.
√ CHECK LIST
A Check date code to make sure pump is within warranty period. Date code is the month and
the year.
( Example: 0311 is March of 2011. Date Code is found on the top of the pump.)
B Make certain that the power source matches the pump requirements. This pump has a dual
voltage motor and can run on 115V or 230V. See pump label for voltage prewired at the
factory.
C If pump does not run, check the GFI or breaker panel switch to make it is in full operation.
D If the pump runs all the time, make sure the pump has been primed correctly. If pump is not
holding the prime, inspect check valve, foot valve, and piping, then reprime.
E If the pump runs but won’t shut off, check pressure switch.
IL1102
MODEL
LIQUID PUMP
LR90197
C
US
UL Std. No. 778
REV
DATE CODE:/CÓDIGO DE FECHA
Made in USA • Hecho en EE.UU.
FLINT & WALLING, INC. • Kendallville, IN 46755 • USA
A
E
S
TAR
®
C
US
LR90197
UL Std. No. 778
ENCLOSURE 3
starwatersystems.com
Pump:
ES05S
Rev:
B
Motor:
98L105
HP:
1/2
PH
1
Hz
60
Volts
115/230
S.F.
1.2
Amps
6.4/3.2
S.F. Amps:
8.6/4.3
RPM
3450
Type
C
Duty:
Cont.
Temp
65C
KVA Code
G
Frame
56L
Ins Class
B
Factory prewired for 115V
Thermally protected automatic
Check voltage of power source
Use copper conductors only
ELECTRICAL HAZARD
Improper installation may result in fi re, explosion, electrical short or injury. Replace all covers
before operating. Ground motor in accordance with local and national electrical codes.
Disconnect power source before touching internal parts. Motors equipped with automatic
protection may restart without warning.
See instruction manual for proper installation procedure.
Se reporter au manuel d’instructions pour suivre la procédure adéquate d’installation.
Consulte el instructive para conocer el procedimiento de instalación correcto.
L1
L2
A
B
L1
L2
A
B
IL0180
YELLOW
115 VOLT
SINGLE PHASE
LINE
230 VOLT
SINGLE PHASE
LINE
WHITE
GRAY
RED
TAN
YELLOW
WHITE
GRAY
RED
TAN
DATE CODE:
0713*
Made in USA
B
IL1351
D
qUICK TROUBLE-SHOOTING CHECKLIST
20
20
20
20
IL1339
RESETRESET
TESTTEST
IL1381
C