beautypg.com

Dquick trouble-shooting checklist – Star Water Systems EL10S User Manual

Page 20

background image

20

CARE AND MAINTENANCE

Winterizing

CAUTION: Drain the entire system if

there is danger of freezing. A drain plug is

provided at the bottom of the pump case for

this purpose. (

Fig 1).

IL1111

PREVENT

PUMP

DAMAGE!
Remove plug

in freezing

weather

1

Please review the following troubleshooting questions before returning a pump as defective.

If you have any questions, please call Customer Service at (800) 742-5044.

√ CHECK LIST

A Check date code to make sure pump is within warranty period. Date code is the month and

the year.

( Example: 0311 is March of 2011. Date Code is found on the top of the pump.)

B Make certain that the power source matches the pump requirements. This pump has a dual

voltage motor and can run on 115V or 230V. See pump label for voltage prewired at the

factory.

C If pump does not run, check the GFI or breaker panel switch to make it is in full operation.
D If the pump runs all the time, make sure the pump has been primed correctly. If pump is not

holding the prime, inspect check valve, foot valve, and piping, then reprime.

E If the pump runs but won’t shut off, check pressure switch.

IL1102

MODEL

LIQUID PUMP

LR90197

C

US

UL Std. No. 778

REV

DATE CODE:/CÓDIGO DE FECHA
Made in USA • Hecho en EE.UU.

FLINT & WALLING, INC. • Kendallville, IN 46755 • USA

A

E

S

TAR

®

C

US

LR90197

UL Std. No. 778

ENCLOSURE 3

starwatersystems.com

Pump:

ES05S

Rev:

B

Motor:

98L105

HP:

1/2

PH

1

Hz

60

Volts

115/230

S.F.

1.2

Amps

6.4/3.2

S.F. Amps:

8.6/4.3

RPM

3450

Type

C

Duty:

Cont.

Temp

65C

KVA Code

G

Frame

56L

Ins Class

B

Factory prewired for 115V

Thermally protected automatic

Check voltage of power source

Use copper conductors only

ELECTRICAL HAZARD

Improper installation may result in fi re, explosion, electrical short or injury. Replace all covers

before operating. Ground motor in accordance with local and national electrical codes.

Disconnect power source before touching internal parts. Motors equipped with automatic

protection may restart without warning.

See instruction manual for proper installation procedure.

Se reporter au manuel d’instructions pour suivre la procédure adéquate d’installation.

Consulte el instructive para conocer el procedimiento de instalación correcto.

L1

L2

A

B

L1

L2

A

B

IL0180

YELLOW

115 VOLT

SINGLE PHASE

LINE

230 VOLT

SINGLE PHASE

LINE

WHITE

GRAY

RED

TAN

YELLOW

WHITE

GRAY

RED

TAN

DATE CODE:

0713*

Made in USA

B

IL1351

D

qUICK TROUBLE-SHOOTING CHECKLIST

20

20

20

20

IL1339

RESETRESET

TESTTEST

IL1381

C

This manual is related to the following products: