PREINSTALLATION CHECKLIST - ALL INSTALLATIONS

FW1088

0611

Supersedes

1108

INSTALLATION INSTRUCTIONS

DO NOT uSE FOR PuMPING OILS, GASOLINE OR ANy PETROLEuM by-PRODuCTS.

Notice to Installer: Instructions must remain with installation.

95 N. Oak St. • Kendallville, IN 46755 • 1-800-345-9422

1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer

before using.

2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These

materials should be retained for future reference.

1.

Make sure there is a properly installed ground

fault circuit interrupter (GFCI) protected circuit available. All

pumps are furnished with provisions for proper grounding to

help protect you against the possibility of electrical shock.

2.

Make certain that the ground fault receptacle

is within the reach of the pump’s power supply cord

DO

NOT uSE AN EXTENSION CORD. Extension cords that

are too long or too light do not deliver sufficient voltage to

the pump motor. But, more important, they could present a

safety hazard if the insulation were to become damaged or

the connection ends were to fall into the sump and become

wet.

3.

Make sure the pump electrical supply cir-

cuit is equipped with fuses or circuit breakers of proper

capacity. A separate branch circuit is recommended, sized

according the National Electrical Code for the current shown

on the pump name plate.

4.

TESTING FOR GROuND. As a safety measure,

each electrical outlet should be checked for ground using

an Underwriters Laboratory Listed circuit analyzer which will

indicate if the power, neutral and ground wires are correctly

connected to your outlet. If they are not, call a qualified

licensed electrician.

5.

Installation and checking of electrical circuits

and hardware should only be performed by a qualified licensed

electrician.

6.

FOR YOUR PROTECTION, ALWAYS DIS-

CONNECT PUMP FROM ITS POWER SOURCE BEFORE

HANDLING.

7.

These pumps are supplied with a 3-prong

grounded plug to help protect you against the possibility of

electrical shock.

DO NOT uNDER ANy CIRCuMSTANCES

REMOVE THE GROuND PIN. The 3-prong plug must be

inserted in a mating 3-prong fault interrupter receptacle.

If

the installation does not have such a receptacle, it must be

changed to the proper type, wired, and grounded in accor-

dance with the National Electrical Code and all applicable

local codes and ordinances.

1.

Check to be sure your power source is ca-

pable of handling the voltage requirements of the motor,

as indicated on the pump name plate.

2.

The installation of automatic pumps with

auxiliary float switches is the responsibility of the installing

party and care should be taken that the tethered float

switch will not hang up on the pumping apparatus or pit

peculiarities and is secured so that the pump will shut off.

It is recommended to use rigid piping and fittings and the

pit be 12" or larger in diameter.

3.

These pumps are not designed or intended

to be used to handle sewage or effluent.

4.

Maximum continuous operating water tem-

perature for standard model pumps must not exceed 77°F

(25°C).

5.

This pump has been evaluated for use with

WATER only.

NOTE: A bATTERy bACKuP SySTEM IS RECOMMENDED

TO PREVENT FLOODING AND/OR PROPERTy DAMAGE

IN THE EVENT OF MECHANICAL MALFuNCTION OR

POwER OuTAGE.

NOTE:

Pumps with the “CSA” mark are tested to UL

standard UL778 and certified to CSA standard C22.2 No.

108.

SEE bELOw FOR LIST OF CAuTIONS

SEE bELOw FOR LIST OF wARNINGS

MODELS 3CEH, 433063

SEE bELOw FOR LIST OF wARNINGS (CONTINuED)

8.

RISK OF ELECTRIC SHOCK. These pumps

have not been investigated for use in swimming pool ar-

eas.

9.

This product contains chemicals known to

the State of California to cause cancer and birth defects
or other reproductive harm.

PUMP PERFORMANCE

Vertical Lift (Ft.)

Gal.

5

50

10

36

15

10

Shut off Head 16 Ft.