Star Water Systems COND1 User Manual
Installation instructions
Product information presented here
reflects conditions at time of pub-
lication. Consult factory regarding
discrepancies or inconsistencies.
S
TAR
®
95 North Oak Street
Kendallville, IN 46755
800-742-5044
INSTALLATION INSTRUCTIONS
MODEL COND-1 Condensate Pump
PREINSTALLATION CHECKLIST - ALL INSTALLATIONS
NOTICE TO INSTALLER: Instructions must remain with installation.
1. To help reduce the risk of electrical shock, a properly
grounded receptacle or control box of grounding type must
be installed and protected by a ground fault circuit interrupter
(GFCI) in accordance with the National Electrical Code and
applicable local codes. If pump is wired direct, a GFCI must
be installed in the control box. (SEE WARNING BELOW)
2. Make certain that the ground fault interrupter protected recep-
tacle or control box is within reach of the pump’s power supply
cord. DO NOT USE AN EXTENSION CORD. Extension cords
that are too long or too light do not deliver sufficient voltage
to the pump motor. But more important, they could present a
safety hazard if the insulation were to become damaged or
the connection end were to fall into a damp or wet area.
3. Make sure the pump's electrical supply circuit is equipped
with fuses or circuit breakers of proper capacity.
A separate
branch circuit, sized according to the National Electrical Code
1. Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before
using.
2. Carefully read all the literature provided to familiarize yourself with specific details regarding installation and use before attempting
the installation. These materials should be retained for future reference.
1. Check to be sure your power source is adequate to handle
the amperage requirements of the motor as indicated on the
pump or unit I.D. tag.
2. All plumbing (discharge and drain lines) must be installed to
meet local codes.
for the current shown on the pump name plate is recom-
mended.
4. TESTING FOR GROUND. As a safety measure, each electri-
cal outlet should be checked for ground using an Underwriters
Laboratory Listed circuit analyzer which will indicate if the power,
neutral and ground wires are correctly connected to your outlet.
If they are not, call a qualified licensed electrician.
5. Installation and checking of electrical circuits and hardware
should only be performed by a qualified licensed electrician.
6. FOR YOUR PROTECTION ALWAYS DISCONNECT PUMP
FROM ITS POWER SOURCE BEFORE HANDLING.
7. According to the state of California (Prop 65), this product
contains chemicals known to the state of California to cause
cancer and birth defects or other reproductive harm.
SEE BELOW FOR
LIST OF CAUTIONS
REFER TO WARRANTY ON PAGE 2.
NOTE: Pumps with the “UL” mark and pumps with the “US” mark
are tested to UL Standard UL778. CSA Certified pumps are
certified to CSA Standard C22.2 No. 108.
SEE BELOW FOR
LIST OF WARNINGS
visit our web site:
starwatersystems.com
021859 E