Star Water Systems FB12DCC (Flint & Walling) User Manual
Sb12dcc, fb12dcc, Silent sentry, 12 volt dc battery backup pump
© Copyright 2013. All rights reserved.
SILENT SENTRY
®
12 VOLT DC BATTERY BACKUP PUMP
1.
Make sure there is a properly grounded 115V
receptacle available. Do not use primary pump circuit.
The location must be within 6' of the control box and
battery. The power supply for your DC control system
plugs directly into the 115V outlet.
DO NOT USE AN
ExTENSION CORD.
2.
Make sure the 115V electrical supply circuit is
equipped with fuses or circuit breakers of proper
capacity.
3. DC emergency pumps are designed for handling clear
water. Do not use in septic tanks to pump effluent or
sewage pits to pump sewage.
4. Repair and service of your DC backup system should
be performed by an authorized service station.
5. The installation of DC automatic backup pumps require
the use of a variable level float switch for operation. It is
the responsibility of the installing party, to ensure that
the float switch will not hang up on the pump apparatus
or pit peculiarities and is secured so the pump will turn
“on” and “off”. It is recommended that the pit be 18" in
diameter or larger to accommodate both a primary and
a DC backup pump.
CAUTION
SEE BELOW FOR LIST OF CAUTIONS
1.
Testing for Ground. As a safety measure each
electrical outlet should be checked for ground using an
Underwriters Laboratory listed circuit analyzer, which
will indicate if the power, neutral and ground wires are
correctly connected to your outlet. If they are not, call
a qualified licensed electrician.
2.
For your protection always disconnect the power
supply from its power source before handling the
components of your DC backup pump or the primary
pump.
3. Installation and checking of electrical circuits and
hardware should be performed by a qualified, licensed
electrician.
4. All electrical and safety codes must be followed in addition
to the National Electrical Code and all applicable local
codes.
5.
It is the owner’s responsibility to check the battery
and battery connection
at least every three
months. Batteries contain acid and caution must
be taken when handling.
6. Risk of electric shock - These pumps have not been
investigated for use in swimming pool areas.
7. According to the state of California (Prop 65), this product
contains chemicals known to the state of California to
cause cancer and birth defects or other reproductive
harm.
NOTICE TO INSTALLER: Instructions must remain with installation.
FW0477
1113
Supersedes
0513
Manufacturers of . . .
“Quality Products since 1866”
95 N. Oak St. • Kendallville, IN 46755
1-800-345-9422
MODEL NO. __________________
DATE CODE: __________________
DATE INSTALLED: _____________
CAUTION
Turbulence caused by high velocity
incoming water can cause the DC pump to airlock.
If this condition exists, the incoming water must be
baffled to avoid excessive turbulence.
SEE BELOW FOR LIST OF WARNINGS
PREINSTALLATION CHECKLIST
1.
Inspect your pump. Occasionally, products are damaged during shipment. If the unit or any of the parts are
damaged, contact your dealer before using.
2.
Read all the installation instructions regarding installing and start up. Retain for future reference.
SB12DCC, FB12DCC
INSTALLATION INSTRUCTIONS