Star Water Systems S1108 User Manual
Crawl space, Pumping system, Quality products since 1866
1
© Copyright 2002. All rights reserved.
1. To reduce the risk of electrical shock, a properly grounded
receptacle of grounding type must be installed and protected
by a ground fault circuit interrupter (GFCI) and in accordance
with national electrical code and local codes.
2. Make certain that the receptacle is within the reach of the
pumps power supply cord. DO NOT USE AN EXTENSION
CORD. Extension cords that are too long or too light do not
deliver sufficient voltage to the pump motor. But more impor-
tant, they could present a safety hazard if the insulation were
to become damaged or the connection end were to fall into the
sump.
3. Testing for Ground. As a safety measure, each electrical outlet
should be checked for ground using an Underwriters Labora-
tory Listed circuit analyzer which will indicate if the power,
neutral and ground wires are correctly connected to your outlet.
If they are not, call a qualified electrician.
4. For electrical safety, it is recommended that a GFCI be in-
stalled.
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM
ITS POWER SOURCE BEFORE HANDLING. Single phase
pumps are supplied with a 3-prong grounded plug to help
protect you against the possibility of electrical shock. DO NOT,
UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND PIN.
To reduce the risk of electrical shock, a properly grounded
receptacle of grounding type must be installed and protected
by a ground fault circuit interrupter (GFCI) in accordance with
national electrical code and local codes.
6. Installation and checking of electrical circuits and hardware
should only be performed by a qualified licensed electrician.
NOTICE TO INSTALLER: Instructions must remain with installation.
CRAWL SPACE
®
PUMPING SYSTEM
S1108
PREINSTALLATION CHECKLIST
FW0131
0202
Supersedes
0701
Manufacturers of . . .
Quality Products since 1866
95 N. Oak St. Kendallville, IN 46755
1-800-345-9422
Through research and development, design, testing and manufacturing, we have been able to bring products to the market that solve
problems that plague consumers, industry, and the environment. This commitment to our customers has enabled them to enjoy returns
of our joint efforts.
1. Inspect your unit. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials
should be retained for future reference.
1. Check to be sure your power source is adequate for handling
the voltage requirements of the motor, as indicated on the
pump or basin plate.
2. Make sure the pump electrical supply circuit is equipped with
fuses or circuit breakers of proper capacity. A separate branch
circuit is recommended, sized according to the National Elec-
trical Code for the current shown on the pump name plate.
3. Pump should be checked frequently for debris and/or build up
which may interfere with the float on or off position. Repair
and service should be performed by an Authorized Service
Station only.
4. A CHECK VALVE MAY BE REQUIRED TO REDUCE UNNEC-
ESSARY CYCLING OF PUMP.
5. Dewatering pumps are not designed or intended for handling
raw sewage.
6. Maximum operating temperature for Crawl Space Drain Pumps
must not exceed 130° F (54° C).
Product information presented here reflects conditions
at time of publication. Consult factory regarding
discrepancies or inconsistencies.