PUMP PRIMING & STARTUP (CONTINUED)

20

20

20

20

IL1339

Breaker Box

7

7. Turn on breaker to start pump. (

Fig. 7)

IMPORTANT: If the pump hums instead of

pumping or turns off repeatedly, shut pump off

immediately.

Check voltage. Make sure your incoming voltage

matches the pump wiring voltage. See wiring

guide in the instructions.

IL1353

5

5. Thread in priming plug and then open optional

ball valve if installed by turning handle to line

up with the pipe.

(Fig. 5)

IL1352

Water Level in

Pump Cavity

4

4. Check to be sure water in pump cavity stays

constant. If water level goes down, it could

indicate a leak in the foot valve, check valve or

suction pipe.

(Fig. 4)

IL1768

Check Valve

Well Point

6

6. PRIMING NOTE: Several priming attempts

may be necessary, depending on the length

of suction pipe and location of check valve if a

well point is being used.