PREINSTALLATION CHECKLIST - ALL INSTALLATIONS
1. Check to be sure your power source is capable of handling the
voltage requirements of the motor, as indicated on the pump
name plate.
2. These pumps are not designed or intended to be used to handle
sewage or effluent.
3. This pump has been evaluated for use with WATER only.
4. Maximum continuous operating water temperature for standard
model pumps must not exceed 104°F (40°C).
5. These pumps are not designed or intended to be used as a
primary or backup sump pump.
Note: Pumps with the "cCSAus" mark are tested to UL Standard
UL778 & CSA Standard C22.2 No. 108.
REFER TO WARRANTY ON PAGE 2.
PERFORMANCE
Your pump is designed to effectively pump clear all storm and drain
waters. Although it will usually pass small particles suspended in
water, grass, heavy mud, sand or pea gravel can clog the pump
and reduce pump performance. This can usually be cleaned out by
backflushing with a garden hose through the discharge. The normal
performance that can be expected is as follows:
HP
GALLONS PER MINUTE AT
DISCHARGE HEIGHT ABOVE
PUMPING LEVEL
SHUT-OFF
HEAD
5 Ft.
10 Ft.
15 Ft.
1/4
30
22
12
20 Ft.
SW0562
0611
Supersedes
0309
DO NOT uSE FOR PuMPING OILS, GASOLINE OR ANY PETROLEuM bY-PRODuCTS.
Notice to Installer: Instructions must remain with installation.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before us-
ing. Do Not remove the test plug in the cover.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials
should be retained for future reference.
1. Make sure there is a properly installed ground fault circuit inter-
rupter (GFCI) protected circuit available. All pumps are furnished
with provisions for proper grounding to help protect you against the
possibility of electrical shock.
2. Make certain that the ground fault receptacle is within the reach
of the pump’s power supply cord DO NOT USE AN EXTENSION
CORD. Extension cords that are too long or too light do not deliver
sufficient voltage to the pump motor. But, more important, they
could present a safety hazard if the insulation were to become
damaged or the connection ends were to fall into the sump and
become wet.
3. Make sure the pump electrical supply circuit is equipped with fuses
or circuit breakers of proper capacity. A separate branch circuit is
recommended, sized according the National Electrical Code for the
current shown on the pump name plate.
4. TESTING FOR GROUND. As a safety measure, each electrical
outlet should be checked for ground using an Underwriters Labo-
ratory Listed circuit analyzer which will indicate if the power, neutral
and ground wires are correctly connected to your outlet. If they are
not, call a qualified licensed electrician.
5. Installation and checking of electrical circuits and hardware should
only be performed by a qualified licensed electrician.
6. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP
FROM ITS POWER SOURCE BEFORE HANDLING.
7. These pumps are supplied with a 3-prong grounded plug to help
protect you against the possibility of electrical shock. DO NOT UN-
DER ANY CIRCUMSTANCES REMOVE THE GROUND PIN. The
3-prong plug must be inserted in a mating 3-prong fault interrupter
receptacle. If the installation does not have such a receptacle, it
must be changed to the proper type, wired, and grounded in ac-
cordance with the National Electrical Code and all applicable local
codes and ordinances.
8. Risk of electric shock. This pump has not been tested for use in
swimming pool areas.
9. According to the state of California (Prop 65), this product contains
chemicals known to the state of California to cause cancer and
birth defects or other reproductive harm.