PRE INSTALLATION CHECKLIST - ALL INSTALLATIONS

1. Check to be sure your power source is capable of

handling the voltage requirements of the motor, as

indicated on the pump name plate.

2. The installation of automatic pumps with variable level

float switches is the responsibility of the installing

party and care should be taken that the tethered float

switch will not hang up on the pumping apparatus or pit

peculiarities and is secured so that the pump will shut off.

It is recommended to use rigid piping and fittings and the

pit be 18" or larger in diameter.

3. Vent hole purpose. It is advisable that all submersible

sump pumps be of the bottom intake design to reduce

clogging and seal failures. If a check valve is incorporated

in the installation, a vent hole (approx. 3/16") must

be drilled in the discharge pipe below the check valve

and pit cover to purge the bottom intake unit of trapped

air. Trapped air is caused by agitation and/or a dry

basin. This vent hole should be checked periodically

for clogging. Water stream will be visible from this hole

during pump run periods.

4. Maximum continuous operating water temperature for

standard model pumps must not exceed 104°F (40°C).

Note: Pumps with the "cCSAus" mark are tested to UL Stan-

dard UL778 & CSA Standard C22.2 No. 108.

FW1195

0611

Supersedes

1109

DO NOT uSE FOR PuMPING OILS,

GASOLINE OR ANy PETROLEuM

by-PRODuCTS.

Notice to Installer: Instructions must remain with installation.

Product information presented

here reflects conditions at time

of publication. Consult fac-

tory regarding discrepancies or

inconsistencies.

1.

Inspect your pump. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer

before using.

Do Not remove the test plug in the cover.

2.

Carefully read the literature provided to familiarize yourself with specific details regarding installation and use.

These materials should be retained for future reference.

1. To reduce the risk of electric shock, install only a circuit

protected by a ground-fault circuit-interruptor (GFCI). All

pumps are furnished with provisions for proper grounding to

help protect you against the possibility of electrical shock.

2. Make certain that the ground fault receptacle is within the

reach of the pump’s power supply cord DO NOT USE AN

EXTENSION CORD. Extension cords that are too long or

too light do not deliver sufficient voltage to the pump motor.

But, more important, they could present a safety hazard if

the insulation were to become damaged or the connection

ends were to fall into the basin and become wet.

3. Make sure the pump electrical supply circuit is equipped

with fuses or circuit breakers of proper capacity. A separate

branch circuit is recommended, sized according the

National Electrical Code for the current shown on the pump

name plate.

4. TESTING FOR GROUND. As a safety measure, each

electrical outlet should be checked for ground using an

Underwriters Laboratory Listed circuit analyzer which will

indicate if the power, neutral and ground wires are correctly

connected to your outlet. If they are not, call a qualified

licensed electrician.

5. Installation and checking of electrical circuits and hardware

should only be performed by a qualified licensed electrician.

6. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP

FROM ITS POWER SOURCE BEFORE HANDLING.

7. These pumps are supplied with a 3-prong grounded plug to

help protect you against the possibility of electrical shock.

DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE

GROUND PIN. The 3-prong plug must be inserted in a

mating 3-prong fault interrupter receptacle. If the installation

does not have such a receptacle, it must be changed to the

proper type, wired, and grounded in accordance with the

National Electrical Code and all applicable local codes and

ordinances.

8. Risk of electric shock. This pump has not been investigated

for use in swimming pool or marine areas.

9. According to the state of California (Prop 65), this product

contains chemicals known to the state of California to cause

cancer and birth defects or other reproductive harm.

SEE bELOW FOR LIST OF CAuTIONS

SEE bELOW FOR LIST OF WARNINGS

INSTALLATION INSTRUCTIONS

These installation instructions are applicable for Model 50TC

REFER TO WARRANTy ON PAGE 2.