5. Optical Surveying
What you have done already:
• You have set up the optical instrument on a tripod over a point of your
choice and measured the instrument height.
• You have selected
Optical from the instrument icon located on the Home
screen or Main Menu.
• You have activated the instrument for use with Survey Pro. See Optical
Mode - Connecting Survey Pro to an Optical Instrument on page 21.
• You have configured the proper settings in the
Job > Settings > Surveying tab.
This tab allows you to configure:
–
Earth Curvature & Refraction correction: To adjust measured zenith angles
for the effects of earth curvature and refraction.
–
PPM: To adjust the measured slope distances for the atmospheric effects
on the EDM.
–
Survey with True Azimuths: Automatically sets the Circle on the
instrument to match the BS Azimuth that is set when pointed at the
backsight.
What you should do now: You have to position and orient the total station in
your local coordinate system before you start measuring points. This can be
done using one of the methods below, by choosing whichever is most
appropriate:
•
Known Point: Station setup on a point with known coordinates.
•
Unknown Point /Resection: Station setup on an unknown point using the
resection method to determine the position of the point.
•
Use Last Setup: This method is made available only after a station has been
set up in the current job. Use it only if you are certain the tripod is still
exactly at the same location as when the last setup was performed, and the
same BS and Circle are being used.
The first two methods are described below. The point or points used should
have previously been stored in or imported into the job.