Possible Cause
Solution
No hydraulic pressure.
Engage hydraulic circuit (wing down).
Product control switch is
off.
Turn product control switch to auto.
Roller is jammed.
Remove roller from meter body and remove
obstruction from meter.
Check air cart node.
Check lights on front of node.
Check meter settings.
Make sure that the meter cal and cal weight is
entered correctly.
Possible Cause
Solution
No field boundry recorded. Create a field boundry.
Agressiveness is on.
Turn aggressiveness off.
Improper look aheads.
Adjust look ahead time.
Possible Cause
Solution
No field boundry recorded. Create a field boundry.
Agressiveness is on.
Turn aggressiveness off.
Improper look aheads.
Adjust look ahead time.
Possible Cause
Solution
No hydraulic pressure.
Check and re-align sensor if necessary.
Product control switch is
off.
Set fan cal to 2.
Check air cart node.
Set diverter to the fan position
Possible Cause
Solution
Speed settings set incor-
rectly
Check speed calibration settings on Loup III
or
Viper Pro™.
Meter Roller Won’t Turn
Outer Opener Sections Engage When Turning
Meter Gate Alarms Going Off
No Fan Speed
No Tractor Speed
9.1 Nodes on SCT
®
Implements
Switchbox Node: Controls on/off/auto/SCT
®
functions
Drill Node: Controls toolbar opener sections 1-8 and packing pressure PWM
signal
Reads: Packing pressure transducer
SCT
®
Node 1: Controls function of meter gate sections 1-16 (Meter 1 & 2)
Reads: proximity sensors 1-16
SCT
®
Node 2: Controls function of meter gate sections 17-24 (Meter 3)
Reads: Proximity sensors 17-24
Product Node: Controls speed of hydraulic drive motors 1-3
Reads: Ultrasonic Bin level sensors.
Fan rpm sensors
Hydraulic drive motor encoder
Single Product Node(s) (Optional): Present on Liquid & NH
3
SCT
®
Sys-
tems, controls all functions pertaining to the Liquid or NH
3
hardware ie; Boom
valves, control valves, flow meters, pressure transducers.
Seed Blockage Node (Optional): Reads the blockage sensors and reports
when runs are clear, dirty or blocked.