4.2.2 Labeled Lodar Receiver Diagram
LED marked “SET”
indicates system is active.
LED marked “5V” Indicates power
supply for control circuits is
OK.
LED’s marked “F1-F2-F3-F4-F5-F6 and M” When ON
indicate an output to that function.
LED marked “FAULT” Indicates an overload is
present; the System cannot be
RESET until overload
is removed. This
LED blinks for 20 seconds when the
Receiver is initially powered. A replacement Transmitter
has to be registered during this 20 second period.
F1
F2
F3
F5
F4
M
F6
Voltage
Working Range: 12 Volts to 36 Volts DC.
Limits: 8 Volts minimum to 40 Volts absolute max.
NOTE: 42 Volt System (48 Volt Max is currently Special Order.)
23
4.2.3 Pairing the Remote
The remote should arrive ready for the customer to use, but if it becomes un-
paired from the receiver or a replacement remote is purchased, it is necessary
to register the remote with the receiver.
1. Switch OFF or DISCONNECT the power to the receiver. By following the
wires from the receiver, back to the harness and disconnecting, OR disconnect-
ing and reconnecting harness at tractor.
2. Switch ON or reconnect the power to the receiver. This opens a 20 second
registration window in the receiver. If you are looking at the receiver circuit
board, the fault LED flashes.
3. Immediately PRESS and HOLD the transmitter green button for a minimum
of 10 seconds during this 20 second window. When the Transmitter is registered
the fault LED goes out, and the set LED comes on.
4.The transmitter can now communicate with the receiver, and a light on the
receiver flashes with each button press on the transmitter
CAUTION! Be sure to stand clear of the fill auger or con-
veyor when using the remote. An unexpected button press
could swing the implement into the operator or a bystand-
er causing bodily harm.
Conveyor Remote
NOTE: A second person may
be required to disconnect
and reconnect power at
tractor to ensure 20 second