Default scheduling configuration for the SX-FI48GPP module
The default scheduling configuration for Weighted Round Robin (WRR), Strict Priority (SP), and mixed
WRR and SP mode for the eight QoS priority (qosp) queues mapped to the four hardware queues is
described in the following table.
Default configuration for 8 to 4 queues for the SX-FI48GPP module
TABLE 21
Hardware Queue
Weighted Round Robin (WRR) mode
Mixed WRR and SP
Strict Priority (SP) mode
3
Weight 82%
Strict Priority
Strict Priority
2
Weight 6%
Weight 40%
Strict Priority
1
Weight 6%
Weight 30%
Strict Priority
0
Weight 6%
Weight 30%
Strict Priority
Note that the above table includes values for default, non-jumbo mode WRR. The hardware queues
are calculated using default qosp values from the Default values for scheduling type for stacking and
stand-alone systems (for FCX and ICX 6450 platforms) table as follows:
•
Front end queue 3= 75% (qosp7) + 7% (qosp6) = 82%
•
Front end queue 2 = 3% (qosp4) + 3% (qosp5) = 6%
•
Front end queue 1 = 3% (qosp2) + 3% (qosp3) = 6%
•
Front end queue 0 = 3% (qosp0) + 3% (qosp1) = 6%
The hardware queues for mixed WRR and SP mode are calculated as follows:
•
Front end queue 3 is Strict Priority as default values for qosp7 and qosp6 are SP
•
Front end queue 2 = 25% (qosp4) + 15% (qosp5) = 40%
•
Front end queue 1 = 15% (qosp2) + 15% (qosp3) = 30%
•
Front end queue 0 = 15% (qosp0) + 15% (qosp1) = 30%
Default scheduling configuration for the ICX 6430
The default scheduling configuration for Weighted Round Robin (WRR), Strict Priority (SP), and mixed
WRR and SP mode for the eight QoS priority (qosp) queues mapped to the four hardware queues for
an ICX 6430 is described in the following table.
Default configuration for 8 to 4 queues (stand-alone system)
TABLE 22
Hardware queue
Weighted Round Robin (WRR) mode
Mixed WRR and SP
Strict Priority (SP) mode
3
Weight 75%
Strict Priority
Strict Priority
2
Weight 10%
Strict Priority
Strict Priority
1
Weight 9%
Weight 70%
Strict Priority
0
Weight 6%
Weight 30%
Strict Priority
Default scheduling configuration for the SX-FI48GPP module