Cm sets communication input data, Xv sets the measurement period – Yokogawa DA100 User Manual
Page 58

IM DA100-11E
6-6
6.1 Setting Command
CM
Sets communication input data.
Mode
Operation mode
Setting
CMp1, p2
p1
Communication input data number:
Stand-alone model : C01 to C30
Expandable model : C01 to C60
P2
Numeric value: -32000 to 32000
Example
Set 300 to the communication input data number
C10.
CMC10, 300
Comments
• This command is effective only with the
optional computation functions.
• he position of the decimal point is selected
according to the position of the decimal point
set for the span with an SO command. So you
can set communications input data without
taking the decimal point into consideration.
RO
Setting hourly/daily/monthly report to
ON/OFF and the time to create the
report
Mode
Setup mode
Setting
ROp1, p2, p3, p4
p1 ON Create hourly report
OFF Hourly report OFF
p2 ON1 Create daily report in standard format
ON2 Create daily report in extended format
OFF Daily report OFF
p3 ON1 Create monthly report in standard
format
ON2 Create monthly report in extended
format
OFF Monthly report OFF
p4 Date and time to create the report
DD HH
DD: Date
HH: Hour
Example
Do not create hourly reports and create daily and
monthly reports in standard format. Create the
monthly report at 10 O'clock on the first day of
every month and the daily report at 10 O'clock
everyday.
ROOFF, ON1, ON1, 01 10
Comments
• Effective only on instruments with the optional
report function.
• The report is output using TS4+device trigger
(GET)+RF.
• Date is set between 01 and 28 and hour is set
between 00 and 23 for p4.
RM
Setting report channel to ON/OFF and
the report computation type
Mode
Setup mode
Setting
RMp1, p2, p3, p4, p5
p1 Report channel number (R01 to R60)
p2 Set the report channel to ON/OFF.
p3 Corresponding channel number
Measurement channel: 001 to 060 for stand-
alone type, 001 to 560 for extended type
Computation channel: A01 to A30 for
stand-alone type, A01 to A60 for extended
type
p4 The type of computation
INST
Instantaneous value at the time
when the report is created.
AVE
Average value
SUM
Summed value
p5 Conversion of the standard unit of time
INTVL No conversion
/sec Convert as the summed value of the
physical amount every second
/min Convert as the summed value of the
physical amount every minute
/hour Convert as the summed value of the
physical amount every hour
/day Convert as the summed value of the
physical amount everyday
Example
Set the summed value of the measurement channel
005 which is measuring the amount of flow in units
of l/min to the report channel, R02.
RMR02, ON, 005, SUM, /min
Comments
• Effective only on instruments with the optional
report function.
• If average value (AVE) is set on p4, minimum
and maximum values are also computed along
with the average value.
• If SUM is set on p4, the following computations
are carried out along with the summed value
from the time when the report was created to
the next report.
For hourly report: Total of the summed values
up to the time the daily report is created.
For daily report: Total of the summed values
up to the time the monthly report is created
Only summed value for monthly report
• The settings p3, p4 and p5 are effective when
p2 is ON.
• The setting p5 is effective only when p4 is set
to SUM.
• Since the sum is computed every measurement
interval using the sampled data, there are cases
when the physical amount per unit amount of
time is measured, the computed result differs
from the actual summed value (the
measurement interval and the unit time are
different). In this case, set the same unit used
for the unit time of the physical amount being
measured to p5. The summed values are
computed using the following converting
equations depending on the parameters.
INTVL
∑
(measured values)
/sec
∑
(measured values)
x
measurement
interval
/min
∑
(measured values)
x
measurement
interval/60
/hour
∑
(measured values)
x
measurement
interval/3600
/day
∑
(measured values)
x
measurement
interval/86400
The unit of the measurement interval is seconds.
XV
Sets the measurement period.
Mode
Setup mode
Setting
XVp1
p1
Measurement interval (0.5, 1, 2, 3, 4, 5,
6, 10, 12, 15, 20, 30, or 60)
Example
Set the measurement period to 10 seconds.
XV10
Comments
• For the measurement period setting time, the
parameter that can be set differs depending on
the A/D integration time and the filter on/off
setting. For each condition, the longest
measurement period is the upper limit. The
longest periods are shown below.