4 command list – Yokogawa DA100 User Manual

Page 47

background image

IM DA100-11E

5-5

Command Format

5

5.4

Command List

Setting Command

Command

Content

Effective mode

SR

Range setting

Operation mode

SN

Unit setting (scale unit)

Operation mode

SA

Alarm setting

Operation mode

SD

Date and time setting

Operation mode

SV

Moving average setting

Operation mode

SY

Setting of copy between channels of channel-set parameters

Operation mode

SX

Group setting

Operation mode

SI

Timer setting

Operation mode

SQ

Match time setting

Operation mode

SL

Event/action setting

Operation mode

SO

Computation expression setting (optional)

Operation mode

SK

Computation constant setting (optional)

Operation mode

CM

Communication input data setting (optional)

Operation mode

XV

Sample rate setting

Setup mode

XI

A/D integration time setting

Setup mode

XQ

Filter setting

Setup mode

XA

Setting related to alarm

Setup mode

XY

Relay reflash setting

Setup mode

XN

Relay AND/OR setting

Setup mode

XD

Relay energizing/deenergizing setting

Setup mode

XH

Relay hold setting

Setup mode

XB

Burnout setting

Setup mode

XJ

Reference junction compensation setting

Setup mode

XG

Setting of computation error handling methods (optional)

Setup mode

RO

Setting the hourly, daily and monthly reports and the time to

Setup mode

create the report

RM

Setting of the report channel

Setup mode

RI

Setting the print setting which is applied at report creation time

Setup mode

VS

Selects the relay that can be turned ON/OFF externally.

Setup mode

XE

Setup setting data establishment

Setup mode

XT

Setting of temperature unit

Setup mode

XZ

Setting for execution, data modification, and data storage in

A/D calibration mode

module in A/D calibration

Control Execution Command

Command

Content

Effective mode

AR

Alarm reset

Operation mode

IR

Timer reset

Operation mode

EX

Computation start/stop/reset/clear

Operation mode

BL

Executing the initial balancing

Operation mode

DR

Report start/stop

Operation mode

RS

System reconstruction

Operation mode

RC

RAM clear (initialization of operation mode setting parameter)

Operation mode

DS

Setting mode selection

All modes

VD

Turn ON/OFF the relays specified by the VS command.

Operation mode

TS

Selection of talker output data

All modes

FM

Measured data output request

Operation mode

RF

Report output request

Operation mode

LF

Setting data output request

All modes

CF

System configuration data output request

All modes

VF

Requests the output of the relay condition.

Operation mode

BO

Byte output order specification

Operation mode

IM

Interrupt mask specification

Operation mode

SM

Axuiliary mask specification

Operation mode

Note

• The execution of a command in a mode different from the effective mode will cause a syntax error. Select a mode in which

the command is effective using the DS command and do the setting and execution.