Yokogawa DO202 2-Wire Dissolved Oxygen Analyzer User Manual
Page 52

IM 12A00A01-61E
Foundation Fieldbus 3-47
error description
resource block
transducer block transducer block transducer block
transducer block transducer block transducer block AI1 (channel = 1)
AI2 (channel = 2)
AI3 (channel = 3)
BLOCK_ERR
DEV_ALARM
BLOCK_ERR
XD_ERROR
PV.status
SV.status
TV.status
OUT.status
OUT.status
OUT.status
primary value
0x80000000
INPUT_FAILURE MECHANICAL_FAILURE
BAD, SENS
BAD, SENS_FAIL
exceeds limits
_ERR
_FAIL
tertiary value
0x40000000
INPUT_FAILURE MECHANICAL_FAILURE
BAD, SENS_FAIL
BAD, SENS_FAIL
exceeds limits
_ERR
temperature
0x20000000
INPUT_FAILURE MECHANICAL_FAILURE
BAD, SENS
BAD, SENS
BAD, SENS_FAIL
BAD, SENS_FAIL
BAD, SENS_FAIL
BAD, SENS_FAIL
sensor open
_ERR
_FAIL
_FAIL
temperature
0x10000000
INPUT_FAILURE MECHANICAL_FAILURE
BAD, SENS
BAD, SENS
BAD, SENS_FAIL
BAD, SENS_FAIL
BAD, SENS_FAIL
BAD, SENS_FAIL
sensor shorted
_ERR
_FAIL
_FAIL
glass impedance
0x08000000
INPUT_FAILURE MECHANICAL_FAILURE
BAD, SENS
BAD, SENS_FAIL
BAD, SENS_FAIL
BAD, SENS_FAIL
exceeds high limit
_ERR
_FAIL
glass impedance
0x04000000
INPUT_FAILURE MECHANICAL_FAILURE
BAD, SENS
BAD, SENS_FAIL
BAD, SENS_FAIL
BAD, SENS_FAIL
exceeds low limit
_ERR
_FAIL
reference impedance
0x02000000
INPUT_FAILURE MECHANICAL_FAILURE
BAD, SENS
BAD, SENS_FAIL
BAD, SENS_FAIL
BAD, SENS_FAIL
exceeds high limit
_ERR
_FAIL
reference impedance
0x01000000
INPUT_FAILURE MECHANICAL_FAILURE
BAD, SENS
BAD, SENS_FAIL
BAD, SENS_FAIL
BAD, SENS_FAIL
exceeds low limit
_ERR
_FAIL
calibration timer expired
0x00800000
NEEDS_MAINT_
BAD, NON
BAD, NON
BAD, NON_SPECIFIC
BAD, NON_SPECIFIC
NOW_ERR
_SPECIFIC
_SPECIFIC
not used
0x00400000
not used
0x00200000
not used
0x00100000
not used
0x00080000
not used
0x00040000
mismatch between FF
0x00020000
NEEDS_MAINT_ ELECTRONICS_FAILURE
BAD, DEV
BAD, DEV
BAD, DEV_FAIL BAD, DEV_FAIL
BAD, DEV_FAIL
BAD, DEV_FAIL
interface and EXA
NOW_ERR
_FAIL
_FAIL
parameter
EXA eeprom failure
0x00010000
NEEDS_MAINT_ DATA_INTEGRITY_ERROR
BAD, DEV
BAD, DEV
BAD, DEV_FAIL BAD, DEV_FAIL
BAD, DEV_FAIL
BAD, DEV_FAIL
NOW_ERR
_FAIL
_FAIL
FF interface eeprom
LOST_STATIC_ERR,
0x00008000
NEEDS_MAINT_ DATA_INTEGRITY_ERROR
BAD, DEV
BAD, DEV
BAD, DEV_FAIL BAD, DEV_FAIL
BAD, DEV_FAIL
BAD, DEV_FAIL
failure
LOST_NV_ERR
NOW_ERR
_FAIL
_FAIL
Hart communication
0x00004000
NEEDS_MAINT_ ELECTRONICS_FAILURE
BAD, DEV
BAD, DEV
BAD, DEV_FAIL BAD, DEV_FAIL
BAD, DEV_FAIL
BAD, DEV_FAIL
failure
NOW_ERR
_FAIL
_FAIL
EXA checksum error
0x00002000
ELECTRONICS_FAILURE
BAD, DEV
BAD, DEV
BAD, DEV_FAIL BAD, DEV_FAIL
BAD, DEV_FAIL
BAD, DEV_FAIL
FF interface checksum
0x00001000
_FAIL
_FAIL
error
resource block out of
OUT_OF_SERVICE_ERR 0x00000800
BAD, NON
BAD, NON
BAD, NON
BAD, NON_SPECIFIC
BAD, NON_SPECIFIC
BAD, NON_SPECIFIC
service
_SPECIFIC
_SPECIFIC
_SPECIFIC
transducer block out of
0x00000400
OUT_OF_
BAD, OUT
BAD, OUT
BAD, OUT_OF
BAD, NON_SPECIFIC
BAD, NON_SPECIFIC
BAD, NON_SPECIFIC
service
SERVICE_ERR
_OF_SERVICE
_OF_SERVICE
_SERVICE
AI1 out of service
0x00000200
BAD, OUT_OF_SERVICE
AI1 in manual mode
0x00000100
AI1 in simulation mode SIMULATE_ACTIVE_ERR 0x00000080
AI1 not scheduled
0x00000040
AI2 out of service
0x00000020
BAD, OUT_OF_SERVICE
AI2 in manual mode
0x00000010
AI2 in simulation mode SIMULATE_ACTIVE_ERR 0x00000008
AI3 out of service
0x00000004
BAD, OUT_OF_SERVICE
AI3 in manual mode
0x00000002
AI3 in simulation mode SIMULATE_ACTIVE_ERR 0x00000001