Yokogawa DO202 2-Wire Dissolved Oxygen Analyzer User Manual
Page 34

IM 12A00A01-61E
Foundation Fieldbus 3-29
3-29
Relative
Index
Index
Parameter
Name
Factory Default
Write
Mode
Explanation
25
1025
FREE_TIME
0
–
Percent of the block processing time that is free to process
additional blocks. EXA does not support this.
26
1026
SHED_RCAS
640000 (2S)
AUTO
Time duration at which to give up on computer writes to function
block RCas locations. Supported only with PID function.
27
1027
SHED_ROUT
640000 (2S)
AUTO
Time duration at which to give up on computer writes to function
block ROut locations. Supported only with PID function.
28
1028
FAULT_STATE
1
–
Condition set by loss of communication to an output block, failure
promoted to an output block or a physical contact. When fail-safe
condition is set, Then output function blocks will perform their
FSAFE actions.
29
1029
SET_FSTATE
1
AUTO
Allows the fail-safe condition to be manually initiated by selecting Set.
30
1030
CLR_FSTATE
1
AUTO
Writing a Clear to this parameter will clear the device fail-safe
state if the field condition, if any, has cleared.
31
1031
MAX_NOTIFY
3
–
Maximum number of unconfirmed notify messages possible.
32
1032
LIM_NOTIFY
3
AUTO
Maximum number of unconfirmed alert notify messages allowed.
33
1033
CONFIRM_TIM
640000 (2S)
AUTO
The minimum time between retries of alert reports.
34
1034
WRITE_LOCK
Not locked
AUTO
If set, no writes from anywhere are allowed, except to clear
WRITE_LOCK. Block inputs will continue to be updated
35
1035
UPDATE_EVT
–
–
This alert is generated by any change to the static data.
36
1036
BLOCK_ALM
–
–
The block alarm is used for all configuration, hardware,
connection failure or system problems in the block. The cause of
the alert is entered in the subcode field. The first alert to become
active will set the Active status in the Status attribute.
As soon as the Unreported status is cleared by the alert
reporting task, another block alert may be reported without
clearing the Active status, if the subcode has changed.
37
1037
ALARM_SUM
Enable
–
The current alert status, unacknowledged states, unreported
states, and disabled states of the alarms associated with the
function block.
38
1038
ACK_OPTION
0xFFFF
AUTO
39
1039
WRITE_PRI
0
AUTO
Priority of the alarm generated by clearing the write lock.
40
1040
WRITE_ALM
–
–
This alert is generated if the write lock parameter is cleared.
41
1041 ITK_VER
4
–
Version number of interoperability test by Fieldbus Foundation
applied to EXA.
42
1042 SOFT_REV
–
EXA software revision number.
43
1043
SOFT_DESC
–
Yokogawa internal use.
44
1044
SIM_ENABLE_
MSG
Null
AUTO
Software switch for simulation function.
45
1045
DEVICE_
STATUS_1
0
–
Device status (VCR setting etc.)
46
1046 DEVICE_
STATUS_2
0
–
Device status (failure or setting error etc.)
47
1047
DEVICE_
STATUS_3
0
–
Device status (function block setting.)
48
1048
DEVICE_
STATUS_4
0
–
Not used.
49
1049
DEVICE_
STATUS_5
0
–
Not used.
50
1050
DEVICE_
STATUS_6
0
–
Not used.
51
1051
DEVICE_
STATUS_7
0
–
Not used.
52
1052
DEVICE_
STATUS_8
0
–
Not used.
53
1053
SOFTDWN_
PROTECT
1
–
Not used.
54
1054
SOFTDWN_
FORMAT
1
–
Not used.
55
1055
SOFTDWN_
COUNT
0
–
Not used.
56
1056
SOFTDWN_
ACT_AREA
0
–
Not used.
57
1057
SOFTDWN_
MOD_REV
1, 0, 0, 0, 0, 0,
0, 0, 0
–
Not used.
58
1058
SOFTDWN_
ERROR
0
–
Not used.