Wa t l o w S e r i e s S D 6 P I D w i t h D e v i c e N e t
■
2 4
■
Table 29. Factory/Calibration Class Attributes
Attribute #
Access
Rule
Name
DeviceNet
Data Type
Description of Attribute
Semantics of Values
1
Get
Revision
UINT
Revision of this object
The revision level of this
object (currently 1)
2
Get
Max Instance
UINT
Max allowed Instances of this
object
Always 1 for this Class
Class Services:
•
0x0E
GET ATTRIBUTE SINGLE
Instance Services:
•
0x0E
GET ATTRIBUTE SINGLE
•
0x10
SET ATTRIBUTE SINGLE
NOTE: All successful Explicit Message Responses
from a SET service will contain no data. The
response will be a two-byte message containing
the requester’s MAC ID and Service Code (with
R/R bit set).
Factory/Calibration Object
Class Code: 67hex
Factory/Calibration Object
The Factory/Calibration Object provides access to parame-
ters that contain diagnostics information, calibration and
restore-parameter functions.
Table 28. Factory/Calibration Revision History
Revision
Description
01
Initial Release
Attribute #
Access
Rule
Name
DeviceNet
Data Type
Description of Attribute
Semantics of Values
130
Get/Set
Alarm 2 Low Temperature
DINT
Set the low alarm set point.
-1999 to 0 (* 1000) if
Sensor Type is set to
Thermocouple or RTD
(default = -999)
-1999 to 9999 (* 1000) if
Sensor Type is set to mA
or Volt.
(default = 32)
131
Get/Set
Alarm 2 Low Process
DINT
Set the low alarm set point.
-1999 to 9999 (* 1000) if
Sensor Type is set to mA
or Volt.
(default = 32)
132
Get/Set
Event Output 1
BOOLEAN
Set event output 1 to an on or
off state.
(0) OFF (default)
(1) ON
133
Get/Set
Event Output 2
BOOLEAN
Set event output 2 to an on or
off state.
(0) OFF (default)
(1) ON