Ras interfaces – Proface APL3000B - Node Box PC User Manual
Page 54
![background image](/manuals/358972/54/background.png)
Chapter 3 Specifications
3-13
RAS Interfaces
D-sub 9 pin socket connector
• Be sure to use only the rated voltage level when using pin #1 (DC+12V) for
external power output. Failure to do so can lead to a unit malfunction or accident.
Interfit Bracket
#4-40 (UNC)
Pin Arrangement
Pin No.
Signal Name
Description
1
+12 V
Output Current: 100mA or less
Output Voltage: DC12V±5%
2
DOUT0(+)
Data out 0(+)
3
DOUT1(+)
Data out 1(+)
4
DIN0(+)
Data in 0(+)
5
DIN1(+)
Data in 1(+)
*1
*1
Can be used for inputting the reset signals.
6
GND
Ground
7
DOUT0(-)
Data out 0(-)
8
DOUT1(-)
Data out 1(-)
9
DINCOM
Data in common
•
For further details of the RAS function, see the “PL3000 Series Reference Manual”.