5 replacing the internal battery, 5 replacing the internal battery -16, Replacing the internal battery – Proface APL3000B - Node Box PC User Manual
Page 137: 16 6.5 replacing the internal battery
PL3000 Series Hardware Manual
6-16
6.5
Replacing the Internal Battery
6.5.1
Replacing the Battery for Backup of Internal Clock Data
The PL unit has an internal battery for backup of internal clock data.
Compatible Battery
Service Life
Lithium Battery CR2032
(Hitachi Maxell, Ltd.)
5 years
• The expected battery service life is 5 years, however the battery may die before
then. It is strongly recommended that you replace the battery regularly.
• When the battery is replaced, the BIOS settings are initialized. Configure the
BIOS settings again after replacing the battery.
There is a danger of explosion if the PL unit’s battery is incorrectly replaced. This battery
should be replaced with equivalent type recommended by Pro-face.
Prior to replacing the battery, be sure to turn OFF the PL unit’s power.
Be careful not to cause a short circuit.
Do NOT to touch any internal parts except the battery and the battery holder.
During the replacement, be extremely careful not to drop the battery onto the PC board
inside the PL unit. This may cause product failure.
Dispose of used batteries according to the battery manufacturer’s instructions.