Page 125: 4 6.2 periodic check points
PL3000 Series Hardware Manual
6-4
6.2
Periodic Check Points
To keep your PL unit in its best condition, please inspect the following points periodically.
PL Operation Environment
Is the surrounding air temperature within the allowable range?
0°C to 50°C (without HDD) 5°C to 50°C (with HDD)
Is the ambient humidity within the specified range?
10 to 90%RH (Not condensing, wet bulb temperature: 39°C or less.
Wet bulb temperature with HDD: 29°C or less.)
Is the operating atmosphere free of corrosive gasses?
When using the PL unit inside a panel, the ambient environment refers to the interior of the panel.
Electrical Specifications
Is the input voltage appropriate?
AC type: AC85 to 265V, 50/60Hz
DC type: DC19.2 to 28.8V
Related Items
Are all power cords and cables connected properly? Have any become loose?
Are all mounting brackets holding the unit securely?
Are there many scratches or traces of dirt on the installation gasket?