Wiring and Connecting the Terminal Block
The table below describes how to connect the power cord to the AC Industrial
Personal Computer:
Step
Action
1
Confirm that the power cord is unplugged from the power supply.
2
Remove the AC terminal block from the power connector and connect the power
cord to the AC terminal block as shown below:
Use 75 °C (167 °F) wire.
Use wire with cross-section 0.75 mm
2
to 2.5 mm
2
(AWG 18 to AWG 12).
Attach the wire ends with screws. Use a slot screwdriver (size 0.6 x 3.5) to tighten
the connector screws.
NOTE: Required torque is: 0.5...0.6 Nm (4.5...5.3 lb-in).
3
Place the terminal block in the power connector at the bottom side of the Industrial
Personal Computer and tighten the screws:
NOTE: The recommended torque to tighten these screws is 0.5 Nm (4.5 lb-in).