Wiring and Connecting the Terminal Block

The table below describes how to connect the power cord to the AC Industrial
Personal Computer:

Step

Action

1

Confirm that the power cord is unplugged from the power supply.

2

Remove the AC terminal block from the power connector and connect the power
cord to the AC terminal block as shown below:

Use 75 °C (167 °F) wire.

Use wire with cross-section 0.75 mm

2

to 2.5 mm

2

(AWG 18 to AWG 12).

Attach the wire ends with screws. Use a slot screwdriver (size 0.6 x 3.5) to tighten
the connector screws.
NOTE: Required torque is: 0.5...0.6 Nm (4.5...5.3 lb-in).

3

Place the terminal block in the power connector at the bottom side of the Industrial
Personal Computer and tighten the screws:

NOTE: The recommended torque to tighten these screws is 0.5 Nm (4.5 lb-in).