Environmental characteristics – Proface PS4800 - 19 Panel PC" User Manual
Page 42
Characteristics
42
Environmental Characteristics
Characteristics
The environmental characteristics of the Industrial Personal Computer are as
follows:
NOTE: IEC 61131-2 and IP65 are not part of UL certification.
Characteristics
Value
Standards
Degree of Protection
IP65, Type 4X (Indoor use only)
when the front USB cover is closed on
the models except for Rear Mount Model
IEC60529, UL50E
Pollution Degree
For use in Pollution Degree 2 environment
EN/IEC 61131-2
Surrounding air temperature dur-
ing operation
0...50
C (32...122 F)
when using HDD running with a fan kit,
SSD or CFast
0...45
C (32...113 F):
when using Gigabit Ethernet
5...45
C (41...113 F):
when using DVD multi drive
EN/IEC 61131-2, UL 508
Storage temperature
– 20...60
C (– 4...140 F)
IEC 60068-2-2 tests Bb,
IEC 60068-2-14 tests Na
Operating altitude
2000 m (6560 ft) max
EN/IEC 61131-2
Vibration
EN/IEC 60068-2-6 Fc
Operation (continuous) for prod-
ucts with SSD or CFast card stor-
age device.
2...9 Hz: 1.5 mm
9...200 Hz: 4.9 m/s
2
5...8.4 Hz: 1.75 mm
8.4...150 Hz: 4.9 m/s
2
Operation (continuous) for prod-
ucts with HDD storage device.
5...100 Hz: 1.225 m/s
2
Operation (occasional) for prod-
ucts with SSD or CFast card stor-
age device.
2...9 Hz: 3 mm
9...200 Hz: 9.8 m/s
2
5...8.4 Hz: 3.5 mm
8.4...150 Hz: 9.8 m/s
2
Operation (occasional) for prod-
ucts with HDD storage device.
5...100 Hz: 2.450 m/s
2
Shock Resistance (in operation)
147 m/s
2
for a duration of 11 ms
IEC 60068-2-27 Ea test
Surrounding air humidity during
operation
10...85 % RH (Wet bulb temperature: 29
C
(84.2
F) max. - no condensation)
EN/IEC 60068-2-78 Cab
Storage humidity
10...85 % RH (Wet bulb temperature: 29
C
(84.2
F) max. - no condensation)
EN/IEC 60068-2-30 Db
Electromagnetic Compatibility
(EMC)
Immunity to High Frequency Interference
EN/IEC 61131-2, IEC 61000-4-x
Electromagnetic Emissions Class A
EN61000-6-4