Relay Output Specifications Q2 to Q7
Output delay and contact
Relay Output Delay
The output delay is illustrated below.
Relay Output Contact
The relay output contact is shown below.
Transistor Source Output Contact
The transistor source output contact is shown below.
Number of outputs
6 relay outputs
Output points per common line - COM1 3 NO contacts
Output points per common line - COM2 2 NO contacts
Output points per common line - COM3 1 NO contact
Maximum load current
2 A per output
8 A per common line
Minimum switching load
0.1 mA/DC0.1 V (reference value)
Initial contact resistance
50 m
Ω (max.)
Mechanical life
20,000,000 operations (min.) (rated load 18,000
operations/h)
Dielectric strength
Between output to internal circuit: AC1500 V rms, 1 min
Between output to terminals (COMs): AC750 V rms, 1
min
Connector insertion/removal durability
100 times (min.)
Output delay - turn on time
10 ms (max.) (Bounce time not included)
Output delay - turn off time
5 ms (max.) (Bounce time not included)
ON
OFF
ON
OFF
Command
Output Relay Status
OFF delay: 5 ms (max.)
ON delay: 10 ms (max.)
Qx (Load)
COM
Terminal block
Internal Circuit
N.O
COM (+)
Output
-V
Internal
Circuit
- AGP3400 - 7.5 DIO HMI" AGP3300 - 5.7 DIO HMI" AGP3600 - 12.1 FLEX Network HMIs" AGP3500 - 10.4 FLEX Network HMI" AGP3400 - 7.5 FLEX Network HMI" AGP3600 - 12.1 CANopen HMI" AGP3500 - 10.4 CANopen HMI" AGP3400 - 7.5 CANOpen HMI" AGP3300 - 5.7 CANopen HMI" LT3200 - 3.8 All-in-One HMI" AGP3300H - 5.7 Handheld HMIs" AGP3750 - 15 Multi-Media HMI" AGP3650 - 12.1 Multi-Media HMIs" AGP3550 - 10.4 Multi-Media HMIs" AGP3450 - 7.5 Multi-Media HMI" AGP3360 - 5.7 Multi-Media HMI" AST3300 - 5.7 Basic HMI" AST3200 - 3.8 Basic HMI" AGP3600 - 12.1 Standard HMIs" AGP3500 - 10.4 Standard HMIs" AGP3400 - 7.5 Standard HMI" AGP3300 - 5.7 Standard HMI" AGP3200 - 3.8 Standard HMI"