Rapid-Air CUT-TO-LENGTH WITH MULTI-STROKE User Manual
Page 52
Cut to Length with Multi Stroke Program
(xxx
*example of fault
2 - motor over temperature
If this screen is displayed then the control cabinet has to be opened and the
Pac-Sci drive has to be checked. To reset the fault, the master on-off switch
has to be cycled which will reset the controller. The material path should be
checked for obstruction and parrallelism to the die. If all this seems to be
satisfactory and another fault occurs the factory should be consulted.
MAIN MENU
F1=JOB # F2=MANUAL
F3=AUTOMATIC CYCLE
F4=REVIEW JOB PROGRAM
F4=JOB REVIEW
Pressing the F4 key will display the following screen. This screen asks for a
sequence number to be reviewed or modified. The program only allows
reviewing of a sequence in the job that is currently active. For an example, if
job #1 had 4 sequences and sequence 1 was not functioning correctly then
put in 01 at this time.
REVIEW OR MODIFY SEQ
file:///C|/Web_develop/cut_to_length_with_multi_stroke_.htm (51 of 66) [12/10/2001 3:44:58 PM]