Rapid-Air CUT-TO-LENGTH WITH MULTI-STROKE User Manual
Page 19

Cut to Length with Multi Stroke Program
To enter this function, turn off the program by depressing the master stop
button. Turn on the program again and push and hold the “clear entry” key,
once the program has started the following screen will be displayed.
**DEFAULT VALUE SETUP
PRESS F1 TO RESET TO
DEFAULT VALUES, PRESS
F4 TO IGNORE CHANGES
**Once F1 has been pressed then all data that had been entered will be reset.
PROGRAM NUMBER DISPLAY
Each servo unit that is shipped has a program number assigned to it. If a
problem occurs and cannot be solved by reloading the program then you will
be asked the program number associated with this servo.
To view the program number, press and hold the “back space” key during the
power up sequence. The program number will be displayed for about 30
seconds. Please find and write down the program number in case it is needed
in the future.
TO HELP YOU ENTER A JOB FROM THE KEYPAD LET’S CREATE AN
EXAMPLE
file:///C|/Web_develop/cut_to_length_with_multi_stroke_.htm (18 of 66) [12/10/2001 3:44:57 PM]