Cut to Length with Multi Stroke Program

Guidelines - 0 means the drive is not faulted and not enabled, while 8 means
the drive is not faulted and enabled. Alternating 8.> means actively inhibiting
CW motion and alternating

8.< means actively inhibiting CCW motion

STATUS LED VALUE FAULT MEANING

(Blinking) 1 1 Velocity feedback (VelFB) over speed

(Blinking) 2 2 Motor Over-Temp

(Blinking) 3 3 Drive Over-Temp

(Blinking) 4 4 Drive I*t

(Blinking) 5 5 1-n Fault (9x3)

(Blinking) 6 6 Control ±12 V supply under voltage

(Blinking) 7 7 Output over current or bus over voltage

(Blinking) 9 9 Not Assigned