beautypg.com

Accessories, Water cooled guns, Warning – Lincoln Electric IM10077 POWER FEED 25M User Manual

Page 66

background image

C-6

ACCESSORIES

C-6

WATER COOLED GUNS

ELECTRIC SHOCK can kill.

• Turn the input power OFF at the dis-

connect switch before working on
this equipment.

• Do not touch electrically hot parts.
• Only qualified personnel should install, use or

service this equipment.

------------------------------------------------------------------------
Python Water Cooled Guns
K2212-xx push-pull guns require both the K590-6
water connection kit and the K2339-1 push-pull gun
connection kit. The hoses from the water connection
kit assemble directly to the push-pull gun bushing as
shown below. Secure the conduit from the python
gun in the gun bushing by using the thumb screw.

To install the K2339-1 Push-Pull Gun Connection Kit
in the POWER FEED™ 25M:

1. Turn power off at the welding power source.

2. Remove the gun from the wire feeder, if attached.

3. Loosen the socket head cap screw that holds the

connector bar against the gun bushing. Important:
Do not attempt to completely remove the socket
head cap screw.

4. Remove the outer wire guide, and push the gun

bushing out of the wire drive. Because of the preci-
sion fit, light tapping may be required to remove the
gun bushing.

5. Disconnect the shielding gas hose from the gun

bushing, if required.

6. Install Adapter, 5/8” L.H. Fitting to the Push-Pull

Bushing.

7. Slide the Push-Pull Bushing into the wire drive.

8. Insert the conduit from the push-pull gun into the

push-pull bushing until the conduit is flush to the
inner wire guide. Secure the conduit with the thumb
screw.

9. Tighten the socket head cap screw to hold the

push-pull bushing tightly to the wire drive.

POWER FEED™ 25M

WARNING

10. Assemble Adapter Fitting to the front of the push-

pull bushing. Attach the electrode cable from gun
to the adapter fitting.

11. Use the adapter fittings to attach one of the water

hoses to the adapter.

12. Attach the other water hose to the water hose of

the of push-pull gun using the Hose Nipple.

13. Connect the control cable from the push-pull gun

to the 7 pin circular connector on the front of the
Power Feed 25M.

Power

Conduit

Gas