Parameter
Definition
P.0
Exit Setup Menu
This option is used to exit the setup menu. When P.0 is displayed, press the Left Button to exit
the setup menu.
P.1
Wire Feed Speed Units
This option selects which units to use for displaying wire feed speed.
English = inches/minute wire feed speed units (default).
Metric = meters/minute wire feed speed units.
P.2
Arc Display Mode
This option selects what value will be shown on the upper left display while welding.
Amps = The left display shows Amperage while welding (default).
WFS = The left display shows Wire Feed Speed while welding.
P.3
Display Options
This setup parameter was previously named "Display Energy"
If the previous software revision had this parameter set to display energy, that selection will
remain.
This option selects the information displayed on the alphanumeric displays while welding. Not all
P.3 selections will be available on all machines. In order for each selection to be included in the
list, the power source must support that feature. A software update of the power source may be
needed to include the features.
Standard Display = The lower displays will continue to show preset information during and after
a weld (default).
Show Energy = Energy is displayed, along with time in HH:MM:SS format.
Show Weld Score = The accumulative weld score result is shown
P.4
Recall Memory with Trigger
This option allows a memory to be recalled by quickly pulling and releasing the gun trigger. To
recall a memory, quickly pull and release the trigger the number of times that correspond to the
memory number. For example, to recall memory 3, quickly pull and release the trigger 3 times.
To recall memory 1, quickly pull and release the trigger the number of user memories plus 1.
Memories cannot be recalled while the system is welding.
Disabled = The gun trigger cannot be used to recall user memories (default).
Enabled = The gun trigger can be used to recall user memories.