Operation – Lincoln Electric IM10077 POWER FEED 25M User Manual
Page 44

B-28
OPERATION
B-28
POWER FEED™ 25M
Parameter
Definition
P.18
Wire Drive Gear Ratio
This option selects the Wire Drive Gear Ratio that will be used. The possible selectable values
are read from the Wire Drive on startup. For semi-automatic systems, if the feedhead board
has dip switches, this option does not appear in the menu. Gear ratio can be selected using the
dip switches.
Note: Changing this value will cause the system to reset.
P.20
Display Trim as Volts Option
This option determines how trim is displayed.
False = The trim is displayed in the format defined in the weld set (default).
True = All trim values are displayed as a voltage.
Note: This option may not be available on all machines. The power source must support this
functionality, or this option will not appear in the menu.
P.22
Arc Start/Loss Error Time
This option can be used to optionally shut off output if an arc is not established, or is lost for a
specified amount of time. Error 269 will be displayed if the machine times out. If the value is set
to OFF, machine output will not be turned off if an arc is not established nor will output be
turned off if an arc is lost. The trigger can be used to hot feed the wire (default). If a value is
set, the machine output will shut off if an arc is not established within the specified amount of
time after the trigger is pulled or if the trigger remains pulled after an arc is lost. This is disabled
while welding in Stick, TIG or Gouge. To prevent nuisance errors, set Arc Start/Loss Error Time
to an appropriate value after considering all welding parameters (run-in wire feed speed, weld
wire feed speed, electrical stick out, etc). To prevent subsequent changes to Arc Start/Loss
Error Time, the setup menu should be locked out by setting Preference Lock = Yes using the
Power Wave Manager software.
P.24
Push Pull Type
Allows operator to choose the Prince option if welding with a Prince Push Pull gun. This gun
requires unique settings to run at the correct WFS.
Note: This option may not be available on all machines. The wire drive must support this func-
tionality, or this option will not appear in the menu.
P.27
Language Select
Selects which language will be displayed on the User Interface.
English (Default)
Italiano
Deutsch Francais
Polski Espanol
P.28
Display Workpoint as Amps Option
This option determines how workpoint is displayed.
False = The workpoint is displayed in the format defined in the weld set (default).
True = All workpoint values are displayed as an amperage.
Note: This option may not be available on all machines. The power source must support this
functionality, or this option will not appear in the menu.
USER DEFINED PARAMETERS