B-11

OPERATION

B-11

Synergic CV programs feature an ideal voltage best
suited for most procedures. Use this voltage as a
starting point and adjust if needed for personal prefer-
ences.

POWER FEED™ 25M

WFS

AMPS

VOLTS

TRIM

220

26.4

SYNERGIC CV VOLTAGE DISPLAY
When the voltage knob is rotated, the display will
show an upper or lower bar indicating if the voltage is
above or below the ideal voltage.

• Preset voltage above ideal

voltage. (upper bar displayed)

• Preset voltage at ideal

voltage. (no bar displayed)

• Preset voltage below ideal

voltage. (lower bar displayed)

Steel
.035

CV CO2

10

START OPTIONS

END OPTIONS

SET

SETUP

EFFECT / RANGE
PINCH EFFECT
(-10.0 to +10.0)

DESCRIPTION

-

EFFECT / RANGE

Preflow Time

Run-in WFS:

Start Procedure

DESCRIPTION

Adjusts the time that shielding

gas flows after the trigger is

pulled and prior to feeding.

Run-In sets the wire feed
speed from the time the trigger
is pulled until an arc is estab-
lished or 2.5 seconds.
The Start Procedure controls
the WFS, Volts at a specified
time at the beginning of the
weld. During the start time, the
machine will ramp up or down
from the Start Procedure to the
preset Welding Procedure.

EFFECT / RANGE

Burnback:

Crater Procedure

DESCRIPTION

The burnback time is the
amount of time that the weld
output continues after the wire
stops feeding. It prevents the
wire from sticking in the puddle
and prepares the end of the
wire for the next arc start.
Crater Procedure controls the
WFS and volts for a specified
time at the end of the weld
after the trigger is released.
During the Crater time, the
machine will ramp up or down
from the Weld Procedure to
the Crater Procedure.

Steel
Steel

Stainless

Stainless

Aluminum 4043

Aluminum 5356

Metal Core

--- --- 81 83

ELECTRODE AND GAS

CO

2

Ar(Mix)
Ar(Mix)

Ar/He/CO

2

Ar
Ar

WIRE SIZE

0.030 0.035 0.045 0.052

---

10 20 24

94 11 21 25

61 31 41 ---
63 33 43 ---

--- 148 71 ---
--- 151 75 ---

WELD MODE

ULTIMARC*

END OPTIONS

START OPTIONS

Pinch controls the arc characte-
-ristics when short-arc welding.

Spot Timer

Adjust the time welding will
continue even if the trigger
is still pulled. This option
has no effect in 4-Step
Trigger Mode.

WELD MODE

ARC CONTROL

*Wave Control in Power Wave

355 and 455 machines.

®

Postflow Time

Adjusts the time that shielding
gas flows after the welding out-
put turns off.

USER INTERFACE Operation, Synergic GMAW(MIG) Welding

Display Operation