Operation – Lincoln Electric IM10077 POWER FEED 25M User Manual
Page 43

B-27
OPERATION
B-27
POWER FEED™ 25M
Parameter
Definition
P.14
Reset Consumable Weight
Use this option to reset the initial weight of the consumable package. Press the Right Button to reset the
consumable weight. This option will only appear with systems using Production Monitoring.
P.16
Push-Pull Gun Knob Behavior
This option determines how the potentiometer on the Push/Pull torch will behave.
• Gun Pot Enabled = The welding wire feed speed is always controlled by the potentiometer on the push-
pull gun (default). The left front panel knob is only used to adjust Start and Crater wire feed speed.
• Gun Pot Disabled = The wire feed speed is always controlled by the left front panel knob. This setting is
useful when the operator wishes to have wire feed speed settings recalled from memories and not have
the potentiometer "overwrite" the setting.
• Gun Pot Proc A = When in procedure A, the welding wire feed speed is controlled by the potentiometer
on the push-pull gun. When in procedure B, the welding wire feed speed is controlled by the left front
panel knob. This setting allows a fixed wire feed speed to be selected in procedure B and not have the
potentiometer "overwrite" the setting when the procedure changes.
P.17
Remote Control Type
This setup parameter was previously named "Spool/Push-Pull"
This option selects the type of analog remote control being used. Digital remote control devices (those
with a digital display) are configured automatically. Not all P.17 selections will be available on all
machines. When P.17 is used to configure the remote control to function in a specific process, the remote
will be ignored in other processes. For example, if P.17 = TIG Amp Control, the remote control will only
function when TIG welding - the remote will be ignored in other processes (MIG, stick and gouge). If P.17
is set to Spool Gun or Push-Pull Gun then set to All Mode Remote, the machine will remember prior value
of P.17 and will operate a Spool Gun or Push-Pull Gun, depending on the prior value of P.17.
Spool Gun = Use this setting while MIG welding with a spool gun that uses a potentiometer used for wire
feed speed control (this setting is backward compatible with "P.17 Gun Selection" = Standard/Spool).
Push-Pull Gun = Use this setting wile MIG welding with a push-pull gun that uses a potentiometer for
wire feed speed control (this setting is backward compatible with "P.17 Gun Selection" = PushPull).
TIG Amp Control = Use this setting while TIG welding with a foot or hand current control device
(Amptrol). While TIG welding, the upper left knob on the User Interface sets the maximum current
obtained when the TIG amp control is at its maximum setting.
Stick/Gouge Rem. = Use this setting while stick welding or gouging with a remote output control device.
While stick welding, the upper left knob on the User Interface sets the maximum current obtained when
the stick remote is at itʼs maximum setting. While gouging, the upper left knob is disabled and the gouging
current is set on the remote control.
All Mode Remote = This setting allows the remote control to function in all weld modes which is how
most machines with 6-pin and 7-pin remote control connections operate. This setting was provided so that
customers with a mix of Lincoln Electric equipment can have consistent remote control behavior across all
of their equipment. (N. American default)
Joystick MIG Gun = Use this setting while MIG welding with a push MIG gun with a joystick control.
Stick, TIG and gouge welding currents are set at the User Interface. (European default)