Operation, B-40 – Lincoln Electric IM10077 POWER FEED 25M User Manual
Page 56

B-40
OPERATION
B-40
POWER FEED™ 25M
WELD:
After upslope, the power source output and the wire
feed speed continue at the weld settings.
CRATER:
As soon as the trigger is released, the wire feed
speed and power source output ramp to the crater
settings throughout the crater time. The time period of
ramping from the weld settings to the crater settings is
called DOWNSLOPE.
CRATER & DOWNSLOPE:
As soon as the trigger is released, the wire feed
speed and power source output ramp to the crater
settings throughout the crater time. The time period of
ramping from the weld settings to the crater settings is
called DOWNSLOPE.
BURNBACK:
After the crater time expires, the wire feed speed is
turned OFF and the machine output continues for the
burnback time.
POSTFLOW:
Next, the machine output is turned OFF and shielding
gas continues until the post flow timer expires.
Shielding
Gas
Idle
Preflow
Stri ke
U pslo pe
Weld
Bu rnba ck
Postflow
Idl e
WFS
On
Off
Run -in
Off
We ld
Off
We ld
Ar
c
E
s
t
abl
i
s
hed
Tr
i
g
g
e
r
P
u
lle
d
Tr
i
g
g
e
r
R
el
eas
ed
2 Step Tr i gger
St art = ON
C rater = ON
B ur nback = ON
1.5 sec ma x .
St ar t
St art t i me
B urnback Ti me
Do wn s lop e
Cr ate r
Crater ti me
Po wer
So ur ce
Output
C r ater
FIGURE B.21
EXAMPLE 3 - 2 STEP TRIGGER: Customized Arc
Start, Crater and Arc End. Sometimes it is advanta-
geous to set specific arc start, crater and arc ending
parameters for the ideal weld. Many times when
welding aluminum crater control is necessary to make
a good weld. This is done by setting Start, Crater
and Burnback functions to desired values. (See
Figure B.21)
For this sequence,
PREFLOW:
Shielding gas begins to flow immediately when the
gun trigger is pulled.
RUN-IN:
After preflow time expires, the power source regulates
to the start output and wire is advanced towards the
work piece at the Run-In WFS. If an arc is not estab-
lished within 1.5 seconds, the power source output
and wire feed speed skips to the weld settings.
START & UPSLOPE:
As soon as the trigger is released, the wire feed
speed and power source output ramp to the crater
settings throughout the crater time. The time period of
ramping from the weld settings to the crater settings is
called DOWNSLOPE.