Installation, Cable connections, Arclink control cables – Lincoln Electric IM10077 POWER FEED 25M User Manual
Page 10

A-3
INSTALLATION
POWER FEED™ 25M
A-3
Figure A.3
A
B
C
D
E
A
B
C
D
E
POWER SOURCE
WIRE FEEDER
Power Source
Pin
Function
A
ArcLink
B
ArcLink
C
"67" voltage sense
D
40 VDC
E
Common
Wire Feeder
Pin
Function
A
ArcLink
B
ArcLink
C
"67" voltage sense
D
40 VDC
E
Common
A
B
C
D
E
A
B
H G
F
E
D
C
K
J
M
L
Function
5-pin trigger con-
nector for push-
only guns.
12-pin connector
for remote control,
foot/hand amptrol,
push-pull guns and
ArcLink peripher-
als
PIN
A
B
C
D
E
A
B
C
D
E
F
G
H
J
K
L
M
Wiring
Trigger
Not used
Common
Dual Procedure Selection
Common
CANL
CANH
75 Remote potentiometer, common
76 Remote potentiometer, wiper
77 Remote potentiometer, 5K
ArcLink Peripheral Sense
Trigger
Trigger
40VDC Common
40VDC +
Pull Motor –
Pull Motor +
CABLE CONNECTIONS
There are two circular connectors on the front of the
POWER FEED™ 25M.
(See 5-pin and 12-pin Figure A.1)
ARCLINK CONTROL CABLES
(See Figure A.3)
ArcLink Control Cables are available in two forms:
• K1543-xx series for most indoor or factory installa-
tions.
• K2683-xx series for outdoor use or when the equip-
ment is frequently moved.
ArcLink/LincNet control cables are special high quality
cables for digital communication. The cables are cop-
per 5 conductor cable in a SO-type rubber jacket.
There is one 20 gauge twisted pair for network com-
munications. This pair has an impedance of approxi-
mately 120 ohms and a propagation delay per foot of
less than 2.1 nanoseconds. There are two 12 gauge
conductors that are used to supply 40VDC to the net-
work. The fifth wire is 18 gauge and is used as an
electrode sense lead.
FIGURE A.1
Use of non-standard cables may lead to system shut-
downs, poor arc starting and wire feeding problems.
The control cables connect the power source to the
wire feeder, and the wire feeder to other wire feeders.
Control cables may be connected end to end to
extend their length. Use a maximum of 200 ft.
(61.0m) of control cable between components.
A
B
C
D
E
Function
5-pin ArcLink
connector.
PIN
A
B
C
D
E
Wiring
ArcLink
ArcLink
67 Electrode Voltage Sense
40VDC
Common
There is one circular connector on the rear of the
POWER FEED™ 25M. Maximum control cable length
is 200 ft (61 m). (See Figure A.2)
FIGURE A.2