IEI Integration TANK-820-H61 v2.03 User Manual
Page 91
TANK-820-H61 Em b e d d e d S ys te m
P a g e 78
Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc.
Advanced
Smart Fan Mode Configuration
Smart Fan control
[Auto PWM Mode]
Temperature of Off
75
Temperature of Start
80
Start PWM
30
Slope(Duty Cycle)
[4]
System Smart Fan control
[Auto Duty-Cycle Mode]
First Boundary Temperature
60
Second Boundary Temperature
50
Third Boundary Temperature
40
Fourth Boundary Temperature
30
Smart Fan Mode Select
--------------------
: Select Screen
↑ ↓: Select Item
Enter
Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized
Defaults
F4: Save & Exit
ESC: Exit
Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc.
BIOS Menu 16: FAN Configuration
Sm art Fan co n tro l [Au to PWM Mo d e]
Use the Smart Fan control BIOS option to configure the CPU Smart Fan.
Full Mode
Fan is on all the time
Manual PWM Mode
The fan spins at the speed set in the manual
setting
Auto PWM Mode
D
EFAULT
The fan adjusts its speed using these
settings:
Temperature of Start
Temperature of Off
Start PWM
Slope (Duty Cycle)
Tem p eratu re o f Off [75]
WARNING:
Setting this value too high may cause the fan to speed up only when