Appendix b – Vestil EPT-30 User Manual
Page 69
69
Curtis PMC 1207/1207A Manual
A-14
APPENDIX A: GLOSSARY
APPENDIX B
SPECIFICATIONS
Table B-1
SPECIFICATIONS: 1207 CONTROLLERS
Nominal input voltage range
24 – 36 V
Maximum operating voltage
45 V
Overvoltage point
48 V
Minimum operating voltage
16 V (= undervoltage point)
Electrical isolation to heatsink
500 V ac (minimum)
PWM operating frequency
15 kHz
Output current*
1207-11XX
1207-21XX
250 amps for 1 minute
300 amps for 30 seconds
200 amps for 2 minutes
210 amps for 2 minutes
150 amps for 5 minutes
160 amps for 5 minutes
100 amps for 1 hour
110 amps for 1 hour
Contactor voltage
= battery voltage
Contactor current (maximum)
1 amp (current limit at 2 amps)
Contactor coil spike protection
internal diode to brake; internal diode from brake to KSI
Shunt driver current (maximum)
2 amps
Shunt driver spike protection
active clamp at 47 V
KSI input voltage
16 – 45 V
KSI input current (typical)
80 mA without programmer; 130 mA with programmer
Logic input current (typical)
10 mA at 24 V
Logic input threshold
8 V
Ambient operating temperature range
-25
°C to 50°C
Heatsink overtemperature cutback
85
°C
Heatsink undertemperature cutback
-25
°C
Package
splash resistant
Weight
1.1 kg (2.5 lbs)
Dimensions
122
Ч 165 Ч 60 mm (4.8" Ч 6.5" Ч 2.35")
*
Output current rating test conditions:
1. Controller cover installed
2. Controller mounted to 230
Ч 305 Ч 3.2 mm (9" Ч 12" Ч 0.125") aluminum plate heatsink
3. Airflow at 4.8 km/h (3 mph) perpendicular to bottom of aluminum plate
4. Duty factor held at 60%
5. Initial heatsink temperature at 20
°C
6. Ambient temperature at 20
°C
7. Current held at tested rating for 120% of time before thermal cutback
B-1