Vestil EPT-30 User Manual
Page 54
54
Curtis PMC 1207/1207A Manual
47
Program Menu Notes
(For more detail on these options, see Appendix A: Glossary of Features and Functions.)
*
Throttle types
Type 1: 5k
Ω–0
Type 2: 0–5V, 0–10V, 3-wire pot, and electronic throttles
Type 3: 0–5k
Ω throttles
†
HPD types
Type 0: no HPD
Type 1: HPD on brake input
Type 2: HPD on KSI
‡
SRO types
Type 0: no SRO
Type 1: SRO on brake input
Type 2: SRO on KSI plus brake input plus a direction input
Type 3: SRO on KSI plus brake input plus forward input
Test Menu
(not all items available on all controllers)
T H R O T T L E
%
Throttle reading, as percent of full
B A T T
V O L T A G E
Battery voltage
H E A T
S I N K
° C
Heatsink temperature
M A X
T E M P
° C
Maximum temperature seen *
M I N
T E M P
° C
Minimum temperature seen *
B R A K E
I N P U T
Brake switch: on/off
S P E E D
I N
Mode switch: on (Mode 1) / off (Mode 2)
E M R
R E V
I N P U T
Emergency reverse switch: on/off
F O R W A R D
I N P U T
Forward switch: on/off
R E V E R S E
I N P U T
Reverse switch: on/off
M A I N
C O N T A C T O R
Main contactor: on/off
F W D
C O N T
Forward contactor: on/off
R E V
C O N T
Reverse contactor: on/off
6 — PROGRAMMER OPERATION
*
Maximum/minimum temperatures recorded
since Diagnostic History was last cleared.