Curtis PMC 1207/1207A Manual
6
WIRING: Standard Configuration (Series Motor)
The basic wiring for series motors with field reversing is shown in Figure 3.
2 — INSTALLATION & WIRING: 1207 Controller
Fig. 3
Standard
wiring diagram
(series motor),
Curtis PMC 1207
controller.
MULTI
MODE
EMERGENCY
REVERSE
A2
A1
REVERSE
CONTACTOR
PRECHARGE RESISTOR
(250
Ω, 5 W)
BRAKE
FORWARD
CONTACTORS
MAIN
REVERSE
SWITCHES
CONTROL
FUSE
M-
A2
B+
B-
FORWARD
CONTACTOR
POWER
FUSE
KEYSWITCH
POLARITY
PROTECTION
DIODE
S1
S2
THROTTLE
5k
Ω–0 (TYPICAL)
MAIN
CONTACTOR
B-
B+
FORWARD
REVERSE
A
The configuration shown in Figure 3 is a typical arrangement for a series motor.
Curtis PMC controllers are designed for use in a wide range of applications, and
accordingly can be installed in a variety of ways to best meet customer needs.
NOTE
: The emergency reverse check feature (wiring shown by dashed line) is a
factory option.
- ABLT-H (7 pages)
- ABLT-H-LP (5 pages)
- ACH-60 (20 pages)
- ALL-T-2-GPT (10 pages)
- ALL-T-2 (9 pages)
- A-LIFT (12 pages)
- AIR-2000 (12 pages)
- AHLT (12 pages)
- AHA-KIT Come-Along kit (5 pages)
- AHA (25 pages)
- AF-xxxx (4 pages)
- APPL-1200-xx (1 page)
- ASP Series (5 pages)
- ATD (6 pages)
- ATP (9 pages)
- ATS (9 pages)
- BC series (12 pages)
- BOL-OR-40-BK (3 pages)
- BOL-SS-42-5.5 (5 pages)
- BOL-SSTOR-42-4.5 (5 pages)
- BT (20, 40, & 60) (12 pages)
- SELF SUPPORTING BRIDGE CRANE (9 pages)
- CART-DS-1000 (15 pages)
- CAN-A (1 page)
- CART-23 & -24, ALL MODELS (12 pages)
- CART-500-SCL (1 page)
- CART-550-SS (15 pages)
- CART-D-FR (18 pages)
- CART-S-FR (18 pages)
- CB-PMPS (13 pages)
- CBS Series (13 pages)
- CB-W-P (1 page)
- CB-W-S (1 page)
- CC-30-MC (59 pages)
- CH series (12 pages)
- COL-3-26-14 (5 pages)
- CYL-CK (1 page)
- CUP-3131 (4 pages)
- CPC (10 pages)
- CP Series (8 pages)
- COL-4-36-23 (5 pages)
- COL-3-26-44 (5 pages)
- COL-3-26-23 (5 pages)
- H series hoppers (13 pages)
- D-150 Dock Seals & Shelter Survey Sheet (1 page)