APPENDIX A: GLOSSARY

APPENDIX A

GLOSSARY OF FEATURES AND FUNCTIONS

Acceleration/deceleration rate

The acceleration rate is the time required for the controller to increase from 0%
to 100% duty factor. The shape of the acceleration curve is controlled by the
dynamic throttle response, which is linear.

If you have a MultiMode™ controller, the acceleration rates in Mode 1 and

in Mode 2 are independently adjustable via the handheld programmer. If you
have a 1207 controller with the MultiMode™ feature disabled (i.e., a single-
mode controller), you can adjust the acceleration rate mechanically via the
appropriate trimpot located on top of the controller.

Anti-tiedown

Before enabling Mode 1 operation, the anti-tiedown function checks that the
mode selection switch has been released after the last cycling of the brake switch.
This feature discourages operators from taping or otherwise “tying down” the
mode switch. If Mode 1 is already selected before the brake is released, the
controller remains in Mode 2 until the mode switch is released and pressed again.

Arcless contactor switching

The controller output duty factor is quickly reduced to zero any time a direction
is de-selected, so that the controller current will be reduced to zero before the
direction contactor drops out.

BB

(= Belly Button; see Emergency reverse)

Brake

The brake must be released (brake input “high”) for the controller to operate.
This is a safety interlock used on most material handling vehicles.

Cycling the brake or KSI clears most faults and enables operation.