Ir pass-through installation and setup, Ir signal tip gnd (ground) ring – Staub Electronics B-500-MTRX-230-8X16 BINARY - HDMI 8X16 MATRIX SWITCH WITH HDMI AND HDBASET OUTPUTS User Manual
Page 14

B-500-MTRX-230 Installation Manual
Pg. 14
© 2013 Binary
™
7.8. IR Pass-Through Installation and Setup
To utilize IR pass-through between a display location and the matrix switcher, install a B-500-RX-230-IR at the display
and use HDBaseT for routing the signal. The matrix switcher and the matrix receiver are equipped with ports to allow
commands to be sent to the display or from the display area. This section details the pinouts and correct use of the IR
pass-through ports.
7.8.1. Matrix Switcher IR Connections
The ports indicated in the diagram are described in detail below. Guides for standard applications are included on the
following pages for reference during setup.
7.8.2. Matrix Switcher IR Port Configuration
All IR connection ports on the B-500-MTRX-230 are 3.5mm mono mini and use this pinout configuration. Consult with
the manufacturer of any attached IR equipment to confirm their pinout matches before use.
1. System All IR Out
This port repeats any command sent from the IR Receiver ports on B-500-RX-230-IR Matrix Receivers connected
to any HDBaseT output.
2. System IR In
3.5mm mono mini IR input port for matrix switcher IR control.
3. System Input Legend
Printed diagram to indicate input and IR connection numbering.
4. IR Output to Source 1 through 16
The IR output from each connected B-500-RX-230-IR is transmitted to the IR OUTPUT TO SOURCE ports.
Commands can be routed to the source selected or to the like-numbered port.
5. IR Input to Room 1 through 16
Use 3.5mm mini-mono cables to connect IR flasher outputs on a control system to these ports to send commands
to displays or equipment located at the B-500-RX-230-IR matrix receiver location. The number corresponds to the
output zone number, so IR Input to Room port 1 will send signals to HDBaseT output 1.
IR Signal (Tip)
GND (Sleeve)
IR Signal
Tip
GND (Ground)
Ring
12V DC 11.2A
INPUT
IR INPUT
TO ROOM
IR INPUT
TO ROOM
IR OUTPUT
TO SOURCE
IR OUTPUT
TO SOURCE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
O
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
UTPUTS
12V DC 11.2A
INPUT
LINK
LINK
LINK
LINK
LINK
LINK
LINK
LINK
LINK
LINK
LINK
LINK
LINK
LINK
LINK
LINK
O
N
1 2
4
5
3