Handpiece lubrication, General accessory recommendations – Foredom Series L User Manual
Page 9

8
Nos. 18, 18D, and 18SJ Handpieces:
These handpieces have a lever on side of handpiece. Push the spring loaded lever in to open col-
let and release the shank of accessory (3/32
″ only). Insert accessory while holding the lever
down. Never push lever down while handpiece or flexible shaft are rotating.
No. 20 Handpiece:
This handpiece has a lever action collet release mechanism. Wait for the motor, flexible shaft and
accessory to come to a complete stop before turning the lever to open collet and remove or
insert accessory (3/32
″ only). Turn lever 90˚ to left or right to open collet and change an acces-
sory. To close the collet turn the lever back to the position parallel to the handpiece.
Nos. 52, 52D, and 52SJ Handpieces:
These quick change handpieces have a unique push/pull collet chuck release mechanism for
rapid accessory changing (3/32
″ only in 52 and 52D). Wait for the motor, flexible shaft, and
accessory to come to a full stop before opening the chuck. After accessory has stopped rotating,
pull the outer grip forward with one hand while holding the back of the handpiece with the other.
Remove the accessory and insert the shank of the new one at least 1
″ (25mm) into the chuck.
Pull the grip all the way back until the chuck snaps closed.
Handpiece Lubrication
(See page 6 for handpiece photos.)
Numbers 8, 8D*, 18, 18D*, 20, 25, 25C, 28, 30
®
, 35, 44T, and 52:
These handpieces have been permanently lubricated with greased-shielded ball bearings and
should absolutely not be lubricated.
Number 10: Lubrication should not be required for the first 2–3 months of continuous use.
Then, approximately every two weeks, remove the sheath connector (it has a standard right hand
thread) to expose the slotted shaft connector and back of handpiece spindle. Clean off any dirt or
old lubricant. Apply only 1 or 2 drops of Foredom oil to the spindle where it attaches to the slot-
ted shaft. Now replace sheath connector.
Number 10D* Handpiece with Duplex Spring Connection: Approximately every 20 hours of
operation apply 1 or 2 drops of Foredom oil into the hole in the duplex spring collar next to the
sheath connector. This will provide sufficient lubrication for both the duplex spring connection
and the handpiece spindle.
Numbers 15 and 15D*: Before disassembling, clean off any dirt to prevent foreign matter from
falling inside the handpiece. Remove the threaded nosepiece assembly carefully with wrench
supplied by turning counterclockwise (right-hand thread). Put two drops of Foredom oil into the
bottom of the threaded hole of the housing and one drop into the nosepiece assembly. Replace
the nosepiece assembly, hold the handpiece upright and run it slowly to distribute the oil.
Lubricate every 100 hours of use.
*Note: All handpieces marked with asterisk have duplex spring connections (flexible springs in
middle). These connections must be lubricated once every 20 hours of operation. Apply about
two drops of oil into the hole on the rear of the connection collar. This should be done with
Foredom
®
Hypodermic type oiler (Part No. 10005).
General Accessory Recommendations
The wide assortment of Foredom
®
accessories makes your flexible shaft power tool very versatile.
Grinding, sanding, carving, engraving, brushing, cutting, buffing and polishing can all be easily
accomplished. Choose the right accessory for your applications from the Foredom Accessory Catalog.
You may purchase accessories from your local dealer, or contact: The Foredom Electric Co. 16 Stony
Hill Road, Bethel, CT 06801, (203)792-8622; or on-line at www.foredom.com.
Always let the speed of the power tool do the work. Avoid forcing the tool or applying too much
pressure. Experience will help you choose the right speed for the work you are doing. It's always