Foredom K.1030 User Manual
Foredom, Safety instructions
FOREDOM
®
Operation and Maintenance Manual for
K.1030 or K.103018 Portable Micromotor Kit
For Your Safety:
Read this Manual before
operating your Foredom
Micromotor Power Tool.
Always wear eye protection
while using the Foredom
Micromotor Handpiece.
Contact Information
For more information on Foredom machines, handpieces or accessories, contact
your local dealer. When no local dealer is available, write, call, fax, or email:
Foredom Electric Company
16 Stony Hill Road, Bethel, CT 06801
Tel: 203-792-8622 Fax: 203-796-7861 Email [email protected]
Visit our website: www.foredom.net
F-1231 n 2/14
Printed in U.S.A.
HP4-310
Control
Unit
HP4-933
Handpiece Cradle
HP8-306
Charger/Adapter
H.MH-130 or H.MH-13018
Handpiece
Optional Components
On/Off
Foot Pedal
HP4-927
Carrying
Case
AP1130
Tool Belt
with Pouch
A-KC300
Safety Instructions
A Micromotor Handpiece is a high speed
rotary power tool which can be danger-
ous and cause serious injury if it is not
used properly. NEVER operate it without
wearing eye protection.
•
ALWAYS wear proper eye and
face protection.
•
ONLY use accessories rated for speeds
of 30,000 rpm or higher when operating
this micromotor.
•
ALWAYS observe the manufacturer’s maxi-
mum speed rating when using any accessory.
•
NEVER use or continue to use any acces-
sory which appears to be damaged, loose,
vibrating, bent, or out of balance. Inspect
each accessory for cracks or flaws before use.
•
ALWAYS insert the shank or arbor of an
accessory or mandrel into the collet or chuck
of the handpiece as far as possible in order to
provide proper support and close the collet or
chuck securely. DO NOT use accessories with
shanks that are less than 1
″ (25mm) long.
•
NEVER use excessive side pressures which
may tend to bend or break the shank or arbor
of an accessory. Let the speed of the acces-
sory do the work.
•
DO NOT stall the motor by jamming or us-
ing excessive pressure on the mounted point,
buff, wheel or accessory. This can result in
damage to the motor.
•
WEAR a dust protector to prevent the inha-
lation of harmful dust or debris from grinding,
carving or other operations performed with
this power tool.
•
DO NOT cover the ventilation slots or
handpiece motor with cloth or tape. Air must
pass freely through the intake and exhaust
ventilation slots to properly cool the motor.
If the power cord or plug to the handpiece is
damaged, repair or replace immediately.
•
NEVER use a damaged power cord or
adapter. ONLY use the power adapter that
came with the K.1030 Kit.
•
USE a dust collector or filter hood to pull
sawdust, grinding dust, or other debris away
from the work area and the micromotor
intake vents.
•
NEVER wear open shoes or sandals. Use
foot-wear that is tough enough to protect
your feet from falling tools.
•
ALWAYS keep both hands and fingers
away from the cutting edge.
•
NEVER cut or exert pressure, toward your
hand or any other part of your body.
•
DO NOT wear loose fitting clothing or
jewelry. Loose clothing or jewelry can be-
come entangled in the tool. Do not wear
items such as neckties, necklaces, or
bracelets when operating power tools.
Secure or tie back long hair.
•
NEVER turn on or start the Handpiece
while the collet is in open (unlocked) posi-
tion. This can damage the handpiece.
•
ALWAYS operate and store it with a bur
or other accessory in the collet and with the
collet in the closed position.
•
NEVER plug the Handpiece into the On/
Off Foot Control Connection Port on the side
of the Control Unit. ONLY plug the Hand-
piece into the Handpiece Connection Port on
the Top of the Control Unit.
•
DO NOT operate the handpiece in the
presence of any flammable liquid or gas.
•
NEVER drop the Control Unit or Micromo-
tor Handpiece.
•
NEVER plug or unplug the power cord
with wet hands.
•
NEVER allow water or liquids to spill onto
any parts of the K.1030 Micromotor Kit.
•
DO NOT operate or store the unit in a
high heat environment such as direct sun,
a parked car in hot weather, near a flame
or stove. Minimum and maximum working
environment temperatures are 32°F – 104°F
(0°C – 40°C).
•
The K.1030 Micromotor has a Lithium
Ion battery that should NEVER be
thrown in the trash. Recycle Lithium Ion
batteries in accordance with local laws.
www.call2recycle.org is a good source of
recycling locations in the US and Canada.
NEVER throw the battery into a fire as
it could explode. Should the electrolytic
chemicals spill and get in your eyes wash
immediately with water. Remove and wash
any clothing or article that has spilled battery
chemicals with water.