Foredom C.SXR-2 User Manual
Parts list, Foredom, C.sxr−2 foot control, 230v
Parts List
C.SXR−2
Foot Control, 230V
FOREDOM
The Foredom Electric Company
16 Stony Hill Rd., Bethel, CT 06801
•
203−792−8622
Fax: 203−796−7861
•
www.foredom.net
}
Qty
Description
Part No.
Item
1
Cover
CP10691
1
1
Trigger Switch, 250V
CP11027
2
2
Screw, 6−32 X 5/16"
CP10571
3
1
Circuit Board, SXR
CP10874
4
1
Base
CP10690
5
1
Base Pad
CP10753
6
1
Male Cordset or Substitute Option
CP10541
7
2
Hinge Pin
CP10584C
8
1
Grommet
CP10578
9
1
Female Cordset
CP10868
10
1
Lock Washer, #8
CP10564
11
1
Ring Terminal
CP10580
12
1
Screw, 8−32 x 1/4"
CP10563
13
3
2 Wire Connector
CP11029
14
1
Set Screw
CP10562
15
1
Spring
CP10588
16
Attach
Ground Screw
to Base
Board
AC Male Plug
to Power Source
Wiring Diagram
BLK
BRN
WHT
W
H
T
(B
LU
)
BLK
GRN
(GRN/YLW)
GRN/YLW
WHT
BLK
Form DN 12/10
Female Receptacle
to Motor
2
5
4
3
6
1
Trigger
Switch
Board
Part No.
Cordset Option
Description
CPOption20 CP10545 No Plug, Europe
CPOption21 CP10553 Male, United Kingdom
CPOption22 CP10554 Male, Continental Europe
CPOption25 CP10555 Male India 10A
CPOption26 CP10556 Male, Austrailia
Position wires around post of Base so wires will not
interfere with Cover travel.
Install Cover over Spring (16) and align holes to Base.
Insert Pins (8) and seat them with hammer.
9.
8.
Install Board and Switch into Base using two Screws (3).
Connect Wires to New Trigger Switch as shown in the
Wiring Diagram.
Push wires all the way in, so that no bare wire
is exposed. On Screw Terminal 1, push the wire lead all the way
into the socket then tighten the screw firmly. Push the other
wire lead all the way into terminal 6. Pull on all the wires, making
sure they are secure.
6.
5.
On older Switches, all the terminals will be push-in, spring clamp
type. On newer Switches, Terminal 1 has a screw for fastening
the wire lead. To remove wires from the push-in terminals, insert
1.3mm [.05in] approximate diameter pin or the blade of a jeweler's
screwdriver all the way into the terminal socket to release the
spring clamp. Grasp the tool and wire and pull them together out
of the socket. If you have difficulty removing the wires from the
push-in terminals and you have wire-cutting, stripping, and
soldering tools, you can cut the wires off where they exit from the
terminals. To prepare the cut wires for installation into the
replacement Switch, strip them back exactly 8.25 mm [5/16 in],
then apply solder to the stripped ends to fuse the strands together.
Remove two Screws (3) from Board (4). After the wires have
been removed from the switch, as instructed in paragraph 4,
remove the switch from the board, insert the new switch in its
place, and follow the instructions in paragraph 5 and 6.
Insert new Trigger Switch into Board.
7.
Remove Cover and drive Pins outward with hammer and punch
to remove.
With a punch and hammer drive two Pins (8) in until Cover (1)
lifts from each side of Base (5).
Disconnect Foot Control from Motor and Wall Outlet.
Instructions for Removing
and Replacing Trigger Switch
1.
3.
2.
4.
For use with LX 230V Motors
and discontinued TX 230V Motors.
4
3
5
6
7
9
8
11
12
13
16
Wire
Connectors
1
15
10
BLU
2
14