beautypg.com

IAI America RCS2-RTC12L User Manual

Page 34

background image

28

5. Connecting to the Controller

When designing an application system using actuators and controllers, incorrect wiring or connection of
each cable may cause unexpected problems such as a disconnected cable or poor contact. This section
explains prohibited handling of cables. Read the information carefully to connect the cables properly.

x Do not let the cable flex at a single point.

x Do not let the cable bend, kink or twist.

x Do not pull the cable with a strong force.

x Do not let the cable receive a turning force at

a single point.

x Do not pinch, drop a heavy object onto or cut

the cable.

x When fixing the cable, provide a moderate

slack and do not tension it too tight.

Steel band
(piano wire)

Bundle loosely.

Use a curly
cable.

Do not use a spiral tube
where the cable flexes
frequently.

This manual is related to the following products: