Wiring Terminal Connections
DKC
Terminal
DK-37 Wiring Reference
Wire Color
+12V
Positive DC supply lead
Red
D0
Wiegand data zero
Green
D1
Wiegand data one
White
LED-G Green
light
Orange
LED-R Red
light
Brown
LED-Y Yellow
light
Blue
BUZ Audible
buzzer
Yellow
TAMP Tamper
indicator
Purple
( - )
Ground
Black
Feedback and Entry Overview
The DK-37 comes with green, yellow, and red LED indicators above the keypad. These three
indicator lights provide feedback during operation. When the DK-37 is in Wiegand mode there is
no yellow feedback light when connected to an access controller. The yellow light is designed to
work with the Securitron DKC Digital Keypad Controller. The three indicator lights are intended
for operation through an access controller either through a dry-contact connection to ground or
an open-collector driver. Please refer to the access controller for information about the meaning
of the indicator lights.
The table below is only for use with Securitron DKC
LED ACTION
MEANING
Red Light
Single Flash
While in programming mode an error was made during
program entry; or
A 5 second timeout occurred at any time during a
programming step.
Red Light
Double Flash
While in programming mode a confirmation that a valid
program entry was made; or
During normal operation the DK-37 was put into or taken
out of lockout mode.
Red Light
Continuous On
During normal operation the relay is energized while the DK-
37 is in relay timer mode.
Red Light
Continuous On
While in normal operation the DK-37 is in passage mode; or
The DK-37 is in toggle mode and the relay is energized.
Yellow Light
Flashing
In programming mode the LED flashes once per second
Yellow Light Continuous On
While in normal operation this indicates that there are no
codes in memory.
Green Light
Single Flash
Key press detected.
Green Light
Continuous On
While in normal mode a 30-second lockout occurred after 16
wrong digits were entered; light turns off after lockout time.
Backlight Double
Flash
While in normal mode a valid code was entered while the
DK-37 was in lockout mode.
The DK-37 is provided with a beeper that can be used to indicate when a button is pressed or
the relay is energized. The beeper functions are detailed in the table below and are valid for use
with the Securitron DKC.