5. GL1 FAIL LOCKED TO FAIL SAFE TRIGGER CONVERSION
Mount unit before initiating conversion of unit.
Disconnect power from the GL1 and
control device.
Ensure that the gate is secured in an
open position so it cannot close and
injure the operator.
Remove the cover from the GL1 by
removing the two screws.
Remove the legs of the spring from
under the roll pin in the trigger. Remove
the spring from the front of the chassis.
DO NOT LOSE THE SPRING.
Using a small screwdriver or punch to
start it moving, remove the Trigger Pin.
Grab the Trigger with one hand and hold
the Transfer Bar back by pressing on the
long roll pin with the other hand.
See also other documents in the category Securitron For Home:
- ASB_Series (2 pages)
- ASCWB-DM62CL (4 pages)
- CWB_Series (2 pages)
- EASB_Series (4 pages)
- GDB (2 pages)
- HHD (6 pages)
- IK_Series (3 pages)
- M34R_Series (10 pages)
- M370 (16 pages)
- M38 (L, S and LS with D and T Options) (14 pages)
- M38 T UPGRADE (2 pages)
- M380BD_C_C2_X MAGNALOCK_Series (20 pages)
- M670 (16 pages)
- M680BDCX (16 pages)
- M32 (16 pages)
- Z-32 (2 pages)
- ZA-32 (3 pages)
- UHB (2 pages)
- TJ-38 (7 pages)
- TDK-1 (1 page)
- SWB-03 (2 pages)
- SMLS_SMSS (4 pages)
- SAM2C-24 (1 page)
- SAM2-24 (11 pages)
- SAM (16 pages)
- 32 REPLACEMENT STRIKE (1 page)
- UNL-12 UNLATCH (10 pages)
- STK-1 (2 pages)
- MUNL-12 (11 pages)
- MM15-TS (1 page)
- MM15 Z-Bracket_Series (1 page)
- MM15 (2 pages)
- Blind Nut (1 page)
- FSUNL_Series (2 pages)
- SCL-12 (4 pages)
- MCL-24 (8 pages)
- SWK (2 pages)
- SPK (2 pages)
- SASM KIT STRIKE (1 page)
- GL1 Quick Start (1 page)
- FMK-SW (7 pages)
- BPSS-10 (7 pages)
- PB5E (2 pages)
- PB5 (2 pages)