Securitron MCL-24 User Manual
Page 2

PN# 500-19100
Page 2
Rev. C, 04/11
A. Physical strength of mounting area. The structural integrity of mounting surfaces must be
strong enough to meet or exceed the holding force of the Magnalock.
B. Protection of the lock from external attack. The Magnalock and the wiring must be
protected to a reasonable degree from potential damage due to intruders or vandals.
C. Convenience and accessibility of area to be protected. The Magnalock assembly should be
installed in a location that will not hinder or create a potential safety hazard to authorized
personnel routinely accessing the protected area.
5.2. Magnalock Body and Strike Plate Installation
The exploded illustration below displays two mounting configurations available using the
hardware provided:
ITEM QTY
PART
NUMBER
NOMENCLATURE/DESCRIPTION
1 1 772-MCL-24
Magnalock
Body
2 1 390-17110
Universal
Bracket
3 1 380-20000
Strike
Plate
(MCL)
4 1 300-11620
#8-32 UNC X 1/2” Long Low Profile Socket Head
Cap Screw
5 2 310-11210
1/2” O.D. X 3/16” I.D. X .093” Neoprene Rubber
Washer
6
1
330-10670
3/32” O.D. X 1/2” Long Roll Pin
7
1
330-12170
Sex Bolt (#8-32 X 7/8” Binder Head)
8
3
300-11790
#10 X 3/4” Long (Phillips) Flat Head Screw
9
4
300-11645
#8-32 UNC X 3/4” Long Socket Head Cap Screw
10
4
300-11710
#6 X 1” Long (Phillips) Pan Head Screw
Mounting LOCK BODY with BRACKET
Mounting STRIKE PLATE with BRACKET
1
3
5
6
2
5
4
10
3
6
1
2
4
9
8
7