Lock/Strike Installation for “B” and “D” Magnalocks

IMPORTANT!

PLEASE READ AND APPLY THIS INFORMATION WHEN ALIGNING/INSTALLING THE

LOCK AND STRIKE. THE ALIGNMENT TOLERANCES INDICATED FOR EACH LOCK

MODEL ARE CONSIDERED CRITICAL FOR THE PROPER OPERATION OF BOTH THE

MAGNETIC BOND SENSING AND DOOR POSITION SENSING SYSTEMS!

SENSOR RANGES (PHYSICAL POSITIONING):
The BondSTAT “B” and DPS “D” Magnalock “Secure Zone” sensing ranges for each lock
model is listed in Table A.

(The Figure 6 illustration is a visual reference to the sensing ranges outlined in Table A).

Secure Sensor Indication Range

(Dimensions from Center)

Model

"X" (+/-)

"Y" (+/-)

M32B/D 9/32"

1/8"

M62B/D 5/16"

1/8"

M82B/D 9/16"

1/8"

Table A

(+)

(+)

(-)

(+)

(-)

(-)

(+)

(-)

X

Y

0

0

Figure 6


5.2.5

In-swinging Door Installation

Figure 7 below illustrates a typical in-swinging door mounting configuration. This installation
requires the use of a face mount style Magnalock (i.e. M32F, M62F, or M82FB) and a “Z” bracket
(Z-32, Z-62, or Z-82) or an adjustable “ZA” bracket (ZA-32/62 or ZA-82) for offsetting the
mounting of the strike must be used. Follow the installation instructions provided with the “Z” or
“ZA” bracket product to correctly install the Magnalock in this arrangement.

THE M62F AND M82FB INCLUDE FIVE (5) MOUNTING HOLES FOR FLEXIBILITY

Figure 7

Z-Bracket or “ZA Bracket

(Dress cover not shown)

Strike Plate

Magnalock

Blind Nuts

and Mounting

Screws

Strike Mounting

Hardware and

T-Nut

Sex Bolt

Door Frame and Stop

Door

Bracket Mounting

Hardware

This manual is related to the following products: