Troubleshooting Guide:
POSSIBLE ISSUES
TROUBLESHOOTING TIPS
No power or low power
Confirm voltage and current at Magnalock to spec
(see page 2)
Check that the DC Power Source is Full Wave Rectified
(Half wave Rectified or AC power is unacceptable)
Reduced Holding Force
Check strike plate position and orientation
Clean surfaces and check for obstructions
LED Error Codes:
Note LED Jumper J4 must be installed (LED ENABLED) for error codes to be visible
CODE
STATE
SOLUTION
SECURE selected color,
on continuously
Normal Operation with
Door Closed
System working normally, SECURE selected
color can be selected with Jumper JP5. See
page 4.
NON-SECURE selected
color, on continuously
Normal Operation with
Door Open
System working normally
RED/GREEN continuous
flash
Processor Error
Check all connections, if error persists
replace unit
3 Fast Flashes of
SECURE color every 5
seconds
Magnet Voltage has
dropped below 85%
Check voltage and current at Magnalock
connections. Check DC Power Source is Full
Wave Rectified.
Single Flash Amber
every 5 seconds
Bond Error – Left Side
Check strike plate position and orientation.
Clean surfaces and check for obstructions.
Double Flash Amber
every 5 seconds
Bond Error – Right Side
Check strike plate position and orientation.
Clean surfaces and check for obstructions.
Off
LED disabled
Check voltage and current at Magnalock
connections. Check that LED is enabled with
a Jumper at JP4
Problems with Installation?
Call Securitron: 1-800-MAGLOCK