TO SOLVE: INTERSECT ROW (Current) and INTERSECTING COLUMN (Wire Distance)

1.0A

20

Gauge

18

Gauge

16

Gauge

14

Gauge

14

Gauge

12

Gauge

10

Gauge

10

Gauge

8

Gauge

.800A

22

Gauge

18

Gauge

18

Gauge

16

Gauge

14

Gauge

12

Gauge

10

Gauge

10

Gauge

8

Gauge

.600A

22

Gauge

20

Gauge

18

Gauge

18

Gauge

16

Gauge

14

Gauge

14

Gauge

12

Gauge

10

Gauge

.400A

22

Gauge

22

Gauge

20

Gauge

18

Gauge

18

Gauge

16

Gauge

14

Gauge

14

Gauge

12

Gauge

.300A

24

Gauge

22

Gauge

22

Gauge

20

Gauge

18

Gauge

18

Gauge

16

Gauge

14

Gauge

14

Gauge

C

U

R
R

E

N

T

.200A

24

Gauge

22

Gauge

22

Gauge

22

Gauge

20

Gauge

18

Gauge

18

Gauge

16

Gauge

14

Gauge

50’

[15m]

100’

[30m]

150’

[46m]

200’

[61m]

300’

[91m]

400’

[122m]

500’

[152m]

750’

[229m]

1000’

[305m]

12VDC

WIRE DISTANCE

Table 1

1.0A

22

Gauge

20

Gauge

20

Gauge

18

Gauge

16

Gauge

14

Gauge

14

Gauge

12

Gauge

10

Gauge

.800A

22

Gauge

22

Gauge

20

Gauge

18

Gauge

18

Gauge

16

Gauge

14

Gauge

14

Gauge

12

Gauge

.600A

24

Gauge

22

Gauge

22

Gauge

20

Gauge

18

Gauge

18

Gauge

16

Gauge

14

Gauge

14

Gauge

.400A

24

Gauge

22

Gauge

22

Gauge

22

Gauge

20

Gauge

18

Gauge

18

Gauge

16

Gauge

14

Gauge

.300A

24

Gauge

24

Gauge

22

Gauge

22

Gauge

22

Gauge

20

Gauge

20

Gauge

18

Gauge

16

Gauge

C

U

R
R

E

N

T

.200A

24

Gauge

24

Gauge

24

Gauge

22

Gauge

22

Gauge

22

Gauge

20

Gauge

20

Gauge

18

Gauge

50’

[15m]

100’

[30m]

150’

[46m]

200’

[61m]

300’

[91m]

400’

[122m]

500’

[152m]

750’

[229m]

1000’

[305m]

24VDC

WIRE DISTANCE

Table 2

The Wire Distance indicated on the table above represents a 2-wire “One-Way” length

from the power supply source to entryway installation area.

The Gauge values specified on the table above represent a 2-wire “Round Trip” length
from the power supply source to entryway installation and returning back to the power
supply source.

IMPORTANT

THE 200’ [61m] WIRE RUN IN EACH TABLE FACTORS A 400’ [122m] ROUND TRIP